All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Monitoring of adipose tissue metabolism using microdialysis and capillary electrophoresis with contactless conductivity detection

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F19%3A43917158" target="_blank" >RIV/00216208:11120/19:43917158 - isvavai.cz</a>

  • Result on the web

    <a href="https://doi.org/10.1016/j.talanta.2018.09.076" target="_blank" >https://doi.org/10.1016/j.talanta.2018.09.076</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.talanta.2018.09.076" target="_blank" >10.1016/j.talanta.2018.09.076</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Monitoring of adipose tissue metabolism using microdialysis and capillary electrophoresis with contactless conductivity detection

  • Original language description

    Metabolism of human adipose tissue during acute exercise is monitored by microdialysis. The metabolites are analysed in the microdialysate using capillary electrophoresis (CE) on a short separation path in combination with a contactless conductivity detector (C4D). Four completely new CE/C4D methods were developed for determination of nutrients and metabolites in 10 µL of microdialysate. All methods are characterised by a short separation time and simple sample preparation based primarily on 4-fold dilution of microdialysate. The intra-day repeatability for the migration time varied in the range 0.4 - 0.9% and that for the peak area equalled 0.7 - 2.4%; the inter-day repeatability of the migration time was in the range 1.2 - 2.3% and the range for the peak area was 2.5 - 5.0%; all the values were measured as RSD. The developed determination was employed for sequenced monitoring of the levels of lactate, glycerol and branched chain amino acids in microdialysates taken from the abdominal adipose tissue during acute physical exercise. The stress test lasted 3 h and the metabolites were monitored at 15 min intervals.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10406 - Analytical chemistry

Result continuities

  • Project

    <a href="/en/project/GA18-04902S" target="_blank" >GA18-04902S: Instrumentation for continuous on-line electtrophoretic monitoring of metabolic processes in living organisms</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2019

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Talanta

  • ISSN

    0039-9140

  • e-ISSN

  • Volume of the periodical

    192

  • Issue of the periodical within the volume

    January

  • Country of publishing house

    NL - THE KINGDOM OF THE NETHERLANDS

  • Number of pages

    7

  • Pages from-to

    380-386

  • UT code for WoS article

    000449443900053

  • EID of the result in the Scopus database

    2-s2.0-85053837405