Assessment of Electrospun and Ultra-lightweight Polypropylene Meshes in the Sheep Model for Vaginal Surgery
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F20%3A43916922" target="_blank" >RIV/00216208:11120/20:43916922 - isvavai.cz</a>
Alternative codes found
RIV/00023698:_____/20:N0000001
Result on the web
<a href="https://doi.org/10.1016/j.euf.2018.07.024" target="_blank" >https://doi.org/10.1016/j.euf.2018.07.024</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.euf.2018.07.024" target="_blank" >10.1016/j.euf.2018.07.024</a>
Alternative languages
Result language
angličtina
Original language name
Assessment of Electrospun and Ultra-lightweight Polypropylene Meshes in the Sheep Model for Vaginal Surgery
Original language description
BACKGROUND: There is an urgent need to develop better materials to provide anatomical support to the pelvic floor without compromising its function. OBJECTIVE: Our aim was to assess outcomes after simulated vaginal prolapse repair in a sheep model using three different materials: (1) ultra-lightweight polypropylene (PP) non-degradable textile (Restorelle) mesh, (2) electrospun biodegradable ureidopyrimidinone-polycarbonate (UPy-PC), and (3) electrospun non-degradable polyurethane (PU) mesh in comparison with simulated native tissue repair (NTR). These implants may reduce implant-related complications and avoid vaginal function loss. DESIGN, SETTING, AND PARTICIPANTS: A controlled trial was performed involving 48 ewes that underwent NTR or mesh repair with PP, UPy-PC, or PU meshes (n=12/group). Explants were examined 60 and 180 d (six per group) post-implantation. INTERVENTION: Posterior rectovaginal dissection, NTR, or mesh repair. OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: Implant-related complications, vaginal contractility, compliance, and host response were assessed. Power calculation and analysis of variance testing were used to enable comparison between the four groups. RESULTS: There were no visible implant-related complications. None of the implants compromised vaginal wall contractility, and passive biomechanical properties were similar to those after NTR. Shrinkage over the surgery area was around 35% for NTR and all mesh-augmented repairs. All materials were integrated well with similar connective tissue composition, vascularization, and innervation. The inflammatory response was mild with electrospun implants, inducing both more macrophages yet with relatively more type 2 macrophages present at an early stage than the PP mesh. CONCLUSIONS: Three very different materials were all well tolerated in the sheep vagina. Biomechanical findings were similar for all mesh-augmented repair and NTR. Constructs induced slightly different mid-term inflammatory profiles. PATIENT SUMMARY: Product innovation is needed to reduce implant-related complications. We tested two novel implants, electrospun and an ultra-lightweight polypropylene textile mesh, in a physiologically relevant model for vaginal surgery. All gave encouraging outcomes.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30214 - Obstetrics and gynaecology
Result continuities
Project
—
Continuities
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Others
Publication year
2020
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
European Urology Focus
ISSN
2405-4569
e-ISSN
—
Volume of the periodical
6
Issue of the periodical within the volume
1
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
9
Pages from-to
190-198
UT code for WoS article
000505780500035
EID of the result in the Scopus database
2-s2.0-85050236539