Intravascular haemolysis after transcatheter aortic valve implantation with self-expandable prosthesis: incidence, severity, and impact on long-term mortality
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F20%3A43920312" target="_blank" >RIV/00216208:11120/20:43920312 - isvavai.cz</a>
Alternative codes found
RIV/00064173:_____/20:N0000104
Result on the web
<a href="https://doi.org/10.1093/eurheartj/suaa098" target="_blank" >https://doi.org/10.1093/eurheartj/suaa098</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/eurheartj/suaa098" target="_blank" >10.1093/eurheartj/suaa098</a>
Alternative languages
Result language
angličtina
Original language name
Intravascular haemolysis after transcatheter aortic valve implantation with self-expandable prosthesis: incidence, severity, and impact on long-term mortality
Original language description
We aimed to determine the incidence, severity, and long-term impact of intravascular haemolysis after self-expanding transcatheter aortic valve implantation (TAVI). We believe this should be evaluated before extending the indications of TAVI to younger low-risk patients. Prospective, academic, single centre study of 94 consecutive patients treated with supra-annular self-expandable TAVI prosthesis between April 2009 and January 2014. Haemolysis at 1-year post-TAVI was defined per the published criteria based on levels of haemoglobin, reticulocyte and schistocyte count, lactate dehydrogenase (LDH), and haptoglobin. All patients had long-term clinical follow-up (6 years). The incidence of haemolysis at 1-year follow-up varied between 9% and 28%, based on different haemolysis definitions. Haemolysis was mild in all cases, no patient had markedly increased LDH levels. The presence of moderate/severe paravalvular aortic regurgitation was associated with haemolysis (7.7% vs. 23.1%, = 0.044) and aortic valve area post-TAVI did not differ between groups with or without haemolysis (1.01 vs. 0.92 cm/m, = 0.23) (definition including schistocyte count). The presence of haemolysis did not have any impact on patient prognosis after 6 years with log-rank test = 0.80. Intravascular haemolysis after TAVI with self-expandable prosthesis is present in 9-28% of patients depending on the definition of haemolysis. The presence of haemolysis is associated with moderate/severe paravalvular aortic regurgitation but not with post-TAVI aortic valve area. Haemolysis is mild with no impact on prognosis.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30201 - Cardiac and Cardiovascular systems
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2020
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
European Heart Journal: Supplements
ISSN
1520-765X
e-ISSN
—
Volume of the periodical
22
Issue of the periodical within the volume
Suppl. F
Country of publishing house
GB - UNITED KINGDOM
Number of pages
7
Pages from-to
"F44"-"F50"
UT code for WoS article
000577169200007
EID of the result in the Scopus database
2-s2.0-85100875290