Comparison of Two Techniques of Superior Vena Cava Flow Measurement in Preterm Infants With Birth Weight <1,250 g in the Transitional Period-Prospective Observational Cohort Study
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F21%3A43921413" target="_blank" >RIV/00216208:11120/21:43921413 - isvavai.cz</a>
Alternative codes found
RIV/00023698:_____/21:N0000011 RIV/00216208:11110/21:10426624 RIV/00064203:_____/21:10426624 RIV/00216208:11130/21:10426624
Result on the web
<a href="https://doi.org/10.3389/fped.2021.661698" target="_blank" >https://doi.org/10.3389/fped.2021.661698</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3389/fped.2021.661698" target="_blank" >10.3389/fped.2021.661698</a>
Alternative languages
Result language
angličtina
Original language name
Comparison of Two Techniques of Superior Vena Cava Flow Measurement in Preterm Infants With Birth Weight <1,250 g in the Transitional Period-Prospective Observational Cohort Study
Original language description
Objectives: Superior Vena Cava (SVC) flow in neonates measured by the standard approach has been validated by different groups around the world. The modified SVC flow measurement technique was recently suggested. The aim of our study was to evaluate standard and modified technique of echocardiography SVC flow measurement in a cohort of extremely preterm neonates in the immediate postnatal period. Methods: Prospective, observational cohort study in a level III neonatal center. Infants with birth weight <1,250 g were eligible for enrolment. SVC flow was measured by echocardiography using standard and modified methods at 6, 18 and 36 h of age. Our primary outcome was equivalency (using raw bounds of -20 to +20 mL/kg/min difference between the paired measurements), agreement and correlation between standard and modified methods of the SVC flow measurements. Results: Thirty-nine infants were enrolled. The mean gestational age of the cohort was 27.4 (SD 2.1) weeks of postmenstrual age, the mean birth weight was 0.95 kg (SD 0.2). The measurements at 6 and 36 h of age were equivalent as defined in the design of the study (p = 0.003 and p = 0.004 respectively; raw bounds -20 to +20 mL/kg/min). At 6 h of age the mean difference (bias) between the measurements was -0.8 mL/kg/min with 95% limits of agreement -65.0 to 63.4 mL/kg/min. At 18 h of age, the mean difference (bias) between the measurements was +9.5 mL/kg/min, with 95% limits of agreement -79.6 to 98.7 mL/kg/min. At 36 h of age the mean difference (bias) between the measurements was -2.2 mL/kg/min with 95% limits of agreement -73.4 to 69.1 mL/kg/min. There was a weak, but statistically significant correlation between the standard and modified method at 6 h of age (r = 0.39, p = 0.04). Conclusion: Both SVC flow echocardiography measurement techniques yielded clinically equivalent results, however due to wide limits of agreement and poor correlation they do not seem to be interchangeable.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30209 - Paediatrics
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2021
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Frontiers in Pediatrics
ISSN
2296-2360
e-ISSN
—
Volume of the periodical
9
Issue of the periodical within the volume
April
Country of publishing house
CH - SWITZERLAND
Number of pages
9
Pages from-to
661698
UT code for WoS article
000641579300001
EID of the result in the Scopus database
2-s2.0-85104650795