The Efficacy and Safety of Hybrid Ablations for Atrial Fibrillation
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F21%3A43921768" target="_blank" >RIV/00216208:11120/21:43921768 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11210/21:10429105 RIV/00064173:_____/21:N0000022
Result on the web
<a href="https://doi.org/10.1016/j.jacep.2021.04.013" target="_blank" >https://doi.org/10.1016/j.jacep.2021.04.013</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jacep.2021.04.013" target="_blank" >10.1016/j.jacep.2021.04.013</a>
Alternative languages
Result language
angličtina
Original language name
The Efficacy and Safety of Hybrid Ablations for Atrial Fibrillation
Original language description
OBJECTIVES: This study sought to comprehensively determine the procedural safety and midterm efficacy of hybrid ablations. BACKGROUND: Hybrid ablation of atrial fibrillation (AF) (thoracoscopic ablation followed by catheter ablation) has been used for patients with nonparoxysmal AF; however, accurate data regarding efficacy and safety are still limited. METHODS: Patients with nonparoxysmal AF underwent thoracoscopic, off-pump ablation using the COBRA Fusion radiofrequency system (Estech) followed by a catheter ablation 3 months afterward. The safety of the procedure was assessed using sequential brain magnetic resonance and neuropsychological examinations at baseline (1 day before), postoperatively (2-4 days for brain magnetic resonance imaging or 1 month for neuropsychological examination), and at 9 months after the surgical procedure. Implantable loop recorders were used to detect arrhythmia recurrence. Arrhythmia-free survival (the primary efficacy endpoint) was defined as no episodes of AF or atrial tachycardia while off antiarrhythmic drugs, redo ablations or cardioversions. RESULTS: Fifty-nine patients (age: 62.5 +- 10.5 years) were enrolled, 37 (62.7%) were men, and the mean follow-up was 30.3 +- 10.8 months. Thoracoscopic ablation was successfully performed in 55 (93.2%) patients. On baseline magnetic resonance imaging, chronic ischemic brain lesions were present in 60% of patients. New ischemic lesions on postoperative magnetic resonance imaging were present in 44.4%. Major postoperative cognitive dysfunction was present in 27.0% and 17.6% at 1 and 9 months postoperatively, respectively. The probability of arrhythmia-free survival was 54.0% (95% CI: 41.3-66.8) at 1 year and 43.8% (95% CI: 30.7-57.0) at 2 years. CONCLUSIONS: The thoracoscopic ablation is associated with a high risk of silent cerebral ischemia. The midterm efficacy of hybrid ablations is moderate.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30201 - Cardiac and Cardiovascular systems
Result continuities
Project
<a href="/en/project/NV16-32478A" target="_blank" >NV16-32478A: EndoMaze HYBRID project-a detailed assessment of efficacy and safety of hybrid ablation of persistent and long-standing persistent atrial fibrillation</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2021
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
JACC: Clinical Electrophysiology
ISSN
2405-500X
e-ISSN
—
Volume of the periodical
7
Issue of the periodical within the volume
12
Country of publishing house
US - UNITED STATES
Number of pages
11
Pages from-to
1519-1529
UT code for WoS article
000744196000008
EID of the result in the Scopus database
2-s2.0-85121001357