Worldwide survey on implantation of and outcomes for conduction system pacing with His bundle and left bundle branch area pacing leads
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F23%3A43924918" target="_blank" >RIV/00216208:11120/23:43924918 - isvavai.cz</a>
Result on the web
<a href="https://doi.org/10.1007/s10840-022-01417-4" target="_blank" >https://doi.org/10.1007/s10840-022-01417-4</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s10840-022-01417-4" target="_blank" >10.1007/s10840-022-01417-4</a>
Alternative languages
Result language
angličtina
Original language name
Worldwide survey on implantation of and outcomes for conduction system pacing with His bundle and left bundle branch area pacing leads
Original language description
BACKGROUND: Adoption and outcomes for conduction system pacing (CSP), which includes His bundle pacing (HBP) or left bundle branch area pacing (LBBAP), in real-world settings are incompletely understood. We sought to describe real-world adoption of CSP lead implantation and subsequent outcomes. METHODS: We performed an online cross-sectional survey on the implantation and outcomes associated with CSP, between November 15, 2020, and February 15, 2021. We described survey responses and reported HBP and LBBAP outcomes for bradycardia pacing and cardiac resynchronization CRT indications, separately. RESULTS: The analysis cohort included 140 institutions, located on 5 continents, who contributed data to the worldwide survey on CSP. Of these, 127 institutions (90.7%) reported experience implanting CSP leads. CSP and overall device implantation volumes were reported by 84 institutions. In 2019, the median proportion of device implants with CSP, HBP, and/or LBBAP leads attempted were 4.4% (interquartile range [IQR], 1.9-12.5%; range, 0.4-100%), 3.3% (IQR, 1.3-7.1%; range, 0.2-87.0%), and 2.5% (IQR, 0.5-24.0%; range, 0.1-55.6%), respectively. For bradycardia pacing indications, HBP leads, as compared to LBBAP leads, had higher reported implant threshold (median [IQR]: 1.5 V [1.3-2.0 V] vs 0.8 V [0.6-1.0 V], p = 0.0008) and lower ventricular sensing (median [IQR]: 4.0 mV [3.0-5.0 mV] vs. 10.0 mV [7.0-12.0 mV], p < 0.0001). CONCLUSION: In conclusion, CSP lead implantation has been broadly adopted but has yet to become the default approach at most surveyed institutions. As the indications and data for CSP continue to evolve, strategies to educate and promote CSP lead implantation at institutions without CSP lead implantation experience would be necessary.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30201 - Cardiac and Cardiovascular systems
Result continuities
Project
—
Continuities
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Others
Publication year
2023
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Interventional Cardiac Electrophysiology
ISSN
1383-875X
e-ISSN
1572-8595
Volume of the periodical
66
Issue of the periodical within the volume
7
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
12
Pages from-to
1589-1600
UT code for WoS article
001163867200001
EID of the result in the Scopus database
2-s2.0-85145828205