High-Output Cardiac Failure Following Insertion of Right Femoral Artery to Left Femoral Vein PTFE Graft for Haemodialysis: A Case Report
Original language description
Arteriovenous grafts used for hemodialysis can produce high-output cardiac failure as a result of shunting of blood through the dialysis access. The following case demonstrates that the problem can occur shortly after graft formation and improved with graft ligation. It caused haemodynamic compromise because of previously undiagnosed, underlying valvular heart disease. It also caused a diagnostic difficulty in the immediate postoperative period as it was mistaken for postsurgical hemorrhage.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
FE - Other fields of internal medicine
OECD FORD branch
—
Result continuities
Project
—
Continuities
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Others
Publication year
2009
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
seminars in dialysis
ISSN
0894-0959
e-ISSN
—
Volume of the periodical
22
Issue of the periodical within the volume
4
Country of publishing house
US - UNITED STATES
Number of pages
3
Pages from-to
—
UT code for WoS article
000269263600030
EID of the result in the Scopus database
—