Continuous glucose monitoring as a screening tool for neonatal hypoglycemia in infants of diabetic mothers
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11130%2F20%3A10395824" target="_blank" >RIV/00216208:11130/20:10395824 - isvavai.cz</a>
Alternative codes found
RIV/68407700:21260/20:00329245 RIV/00064203:_____/20:10395824
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=ZL~9UZq4yM" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=ZL~9UZq4yM</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1080/14767058.2018.1533941" target="_blank" >10.1080/14767058.2018.1533941</a>
Alternative languages
Result language
angličtina
Original language name
Continuous glucose monitoring as a screening tool for neonatal hypoglycemia in infants of diabetic mothers
Original language description
OBJECTIVE: To assess the plausibility of using the continuous glucose monitoring as a sole source of data for the screening of the neonatal hypoglycemia. STUDY DESIGN: Infants of mothers with diabetes were screened for neonatal hypoglycemia (less than 2.5 mmol/l after 4 h of life). Initial measurement was performed using point of care analyzer. We applied continuous glucose monitoring system subsequently. Infants were monitored up to 5 days or until discharge. RESULTS: Out of 32 infants 11 had postnatal hypoglycemia resolved within 12 h of life. Two infants had hypoglycemia found due to continuous glucose monitoring after 24 h of life when sufficient feeding was established and they did not show any signs of hypoglycemia. We did not have any false negative measurements. No infant showed clinical signs of neonatal hypoglycemia. CONCLUSIONS: Continuous glucose monitoring is plausible and safe to use for screening of neonatal hypoglycemia. It operates well within the range that is accepted as safe for neurodevelopment. In addition, it can be used after first day of life where regular screening ends. Limitation of this method is possible alarm negligence of caregivers.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30105 - Physiology (including cytology)
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2020
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
The Journal of Maternal-Fetal & Neonatal Medicine
ISSN
1476-7058
e-ISSN
—
Volume of the periodical
33
Issue of the periodical within the volume
11
Country of publishing house
GB - UNITED KINGDOM
Number of pages
6
Pages from-to
1889-1894
UT code for WoS article
000521652200012
EID of the result in the Scopus database
2-s2.0-85059021185