Modified MR scoring system for assessment of sonographically indeterminate ovarian and adnexal masses in the absence of dynamic contrast-enhanced
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11130%2F24%3A10474428" target="_blank" >RIV/00216208:11130/24:10474428 - isvavai.cz</a>
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=ltHs0je2r5" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=ltHs0je2r5</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/bjr/tqad005" target="_blank" >10.1093/bjr/tqad005</a>
Alternative languages
Result language
angličtina
Original language name
Modified MR scoring system for assessment of sonographically indeterminate ovarian and adnexal masses in the absence of dynamic contrast-enhanced
Original language description
OBJECTIVES: Dynamic contrast-enhanced (DCE) MRI is not available in all imaging centres to investigate adnexal masses. We proposed modified magnetic resonance (MR) scoring system based on an assessment of the enhancement of the solid tissue on early phase postcontrast series and diffusion-weighted imaging (DWI) with apparent diffusion coefficient (ADC) map and investigated the validity of this protocols in the current study. MATERIALS AND METHODS: In this cross-sectional retrospective study, pelvic MRI of a total of 245 patients with 340 adnexal masses were studied based on the proposed modified scoring system and ADNEX MR scoring system. RESULTS: Modified scoring system with the sensitivity of 87.3% and specificity of 94.6% has an accuracy of 92.1%. Sensitivity, specificity, and accuracy of ADNEX MR scoring system is 96.6%, 91%, and 92.9%, respectively. The area under the receiver operating characteristic curve for the modified scoring system and ADNEX MR scoring system is 0.909 (with 0.870-0.938 95% confidence interval [CI]) and 0.938 (with 0.907-0.961 95% CI), respectively. Pairwise comparison of these area under the curves showed no significant difference (P = .053). CONCLUSIONS: Modified scoring system is less sensitive than the ADNEX MR scoring system and more specific but the accuracy is not significantly different. ADVANCES IN KNOWLEDGE: According to our study, MR scoring system based on subjective assessment of the enhancement of the solid tissue on early phase postcontrast series and DWI with ADC map could be applicable in imaging centres that DCE is not available.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30224 - Radiology, nuclear medicine and medical imaging
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2024
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
British Journal of Radiology
ISSN
0007-1285
e-ISSN
1748-880X
Volume of the periodical
97
Issue of the periodical within the volume
1153
Country of publishing house
GB - UNITED KINGDOM
Number of pages
9
Pages from-to
150-158
UT code for WoS article
001150505800016
EID of the result in the Scopus database
2-s2.0-85183469918