Biomechanical comparison of a transiliac internal fixator and two iliosacral screws in transforaminal sacral fractures: a finite element analysis
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11140%2F15%3A10283176" target="_blank" >RIV/00216208:11140/15:10283176 - isvavai.cz</a>
Alternative codes found
RIV/49777513:23520/15:43927427 RIV/00669806:_____/15:10283176
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Biomechanical comparison of a transiliac internal fixator and two iliosacral screws in transforaminal sacral fractures: a finite element analysis
Original language description
Purpose: Vertically unstable sacral transforaminal fractures can be stabilized with a transiliac internal fixator (TIFI) or two iliosacral screws (IS). This study was designed to compare stiffness between TIFI and IS. Methods: Using CT images finite element model of the pelvis was developed. Denis II type fracture was simulated and fixed either with TIFI or two IS. The sacral base was loaded vertically (250-500 N), displacement magnitudes on medial and lateral fracture surface and the maximum bone stress were calculated. The intact pelvis was used as a reference. Stiffness was determined by linear regression of load and dislocation, computed stiffness ratio %. Von Mises stress was expressed as % ratio, evaluation of colour mapping was made. Results: The mean stiffness ratio medially in TIFI was 75.22 %, in IS 46.54 % (p=0.00005), laterally in TIFI 57.88 %, in IS 44.74 % (p=0.03996). Von Mises stress ratio of TIFI was 139.27 %, of IS 565.35 % (p < 0.00001). Conclusions: Significantly hi
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
FI - Traumatology and orthopaedics
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/ED1.1.00%2F02.0090" target="_blank" >ED1.1.00/02.0090: NTIS - New Technologies for Information Society</a><br>
Continuities
S - Specificky vyzkum na vysokych skolach
Others
Publication year
2015
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Acta of Bioengineering and Biomechanics
ISSN
1509-409X
e-ISSN
—
Volume of the periodical
17
Issue of the periodical within the volume
1
Country of publishing house
PL - POLAND
Number of pages
11
Pages from-to
39-49
UT code for WoS article
000354024600005
EID of the result in the Scopus database
2-s2.0-84929164388