Iodine Content Analysis Using Dual-Energy Computed Tomography as a Biomarker of Transitional Cell Carcinoma, an Experience with Separation of the Clotted Blood and Tumorous Tissue
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11140%2F18%3A10366605" target="_blank" >RIV/00216208:11140/18:10366605 - isvavai.cz</a>
Alternative codes found
RIV/00669806:_____/18:10366605
Result on the web
<a href="http://ar.iiarjournals.org/content/38/1/541.abstract" target="_blank" >http://ar.iiarjournals.org/content/38/1/541.abstract</a>
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Iodine Content Analysis Using Dual-Energy Computed Tomography as a Biomarker of Transitional Cell Carcinoma, an Experience with Separation of the Clotted Blood and Tumorous Tissue
Original language description
Background/Aim: The aim of this study was to evaluate the possibility to discriminate the blood clot from tumorous tissue in the assessment of transitional cell carcinoma (TCC), when CT data are used only from single-phase dual-energy CT (DECT). Materials and Methods: A total of 18 patients were included into the retrospective analysis of the prospectively collected data (the average age was 67.3 years, range=62-79 years, 12 males, 6 females). DECT was performed in all patients after intravenous administration of the iodinated contrast material. DECT analysis using three-material decomposition algorithm was used to discriminate blood and enhancing tumorous tissue. In all patients, TCC was detected and subsequently kidney surgery or endoscopy was performed within the next two weeks. The findings were compared with DECT results. Results: In our cohort of patients we found 9 TCC of the renal pelvis or ureter and 7 TCC of the urinary bladder. The accuracy of the TCC detection was 94% (17/18). The presence of coagulated blood within the urinary collecting system together with a tumor was detected in 7 CT examinations. The blood coagulum without a confirmed malignant tumor was found in one case with false positive DECT finding. In other 6 cases bleeding was confirmed during surgery or endoscopy (accuracy 87%). Conclusion: The dual-energy data analysis enables discrimination of a blood clot from tumorous tissue. It helps in detection of UCC in cases when the excretion potential of the kidneys is decreased due to fulfillment of the collecting system with blood clots.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30224 - Radiology, nuclear medicine and medical imaging
Result continuities
Project
<a href="/en/project/ED2.1.00%2F03.0076" target="_blank" >ED2.1.00/03.0076: Biomedical Centre of the Faculty of Medicine in Pilsen</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2018
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Anticancer Research
ISSN
0250-7005
e-ISSN
—
Volume of the periodical
38
Issue of the periodical within the volume
1
Country of publishing house
GR - GREECE
Number of pages
5
Pages from-to
541-545
UT code for WoS article
000419130100073
EID of the result in the Scopus database
2-s2.0-85039799998