Substitution of citrate with tissue plasminogen activator (rt-PA) for catheter lock does not improve patency of tunnelled haemodialysis catheters in a randomised trial
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11140%2F21%3A10423693" target="_blank" >RIV/00216208:11140/21:10423693 - isvavai.cz</a>
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=Wsmk.fmHYR" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=Wsmk.fmHYR</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1186/s12882-021-02243-y" target="_blank" >10.1186/s12882-021-02243-y</a>
Alternative languages
Result language
angličtina
Original language name
Substitution of citrate with tissue plasminogen activator (rt-PA) for catheter lock does not improve patency of tunnelled haemodialysis catheters in a randomised trial
Original language description
Backround: The study aim was to establish if substitution of citrate with rt-PA for catheter lock once weekly can reduce the incidence of catheter-related blood stream infections (CR-BSI) or improve patency of tunneled haemodialysis catheters. Methods: All incident patients undergoing insertion of a tunneled haemodialysis catheter were screened and included except those suffering infection or using oral anticoagulation. Study participants were randomized into two arms according to the solution applied as catheter lock: receiving either trisodium citrate (Citra-LockTM 4%) only or rt-PA (Actilyse (R) 1 mg/ml) on the middle session each week with citrate used on the first and third sessions. The incidence of CR-BSI (confirmed by positive blood culture), catheter non-function (complete obstruction), and malfunction (blood flow < 250 ml/min) was recorded. Statistical significance was tested with ANOVA, post hoc analysis was performed by means of multiple linear regression. Results: Totally, 18 patients were included and followed during 655 haemodialysis sessions. No episode of CR-BSI was detected while 6 catheter non-functions (0.9% sessions) and 101 malfunctions (15.4% sessions) were recorded. The incidence of both events was equal between the study arms: 4 non-functions and 55 malfunctions in the rt-PA arm and 2 non-functions and 46 malfunctions in the citrate arm (p = 0.47 and p = 0.24, respectively). Additionally, the mean blood flow achieved did not differ significantly between the arms: 326 +/- 1,8 and 326 +/- 1,9 ml/min (p = 0.95) in rt-PA and citrate arms, respectively. Post hoc analysis identified time elapsed since previous session (beta = 0.12, p = 0.005) and malfunction on previous session (beta = 0.25, p < 0.001) as significant factors affecting the occurrence of malfunction. By contrast, the study arm, rt-PA application on previous session, and catheter vintage did not enter the model. Conclusion: Substitution of citrate with rt-PA for catheter lock does not reduce the incidence of catheter malfunction neither does it affect the blood flow achieved during haemodialysis. Catheter patency is related rather to the time interval between sessions and to previous malfunction (thus probably reflecting undefined individual factors). The incidence of CR-BSI within pre-selected haemodialysis population is sporadic (less than 1 per 4.3 patient years in our sample).
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30217 - Urology and nephrology
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2021
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
BMC Nephrology
ISSN
1471-2369
e-ISSN
—
Volume of the periodical
22
Issue of the periodical within the volume
1
Country of publishing house
GB - UNITED KINGDOM
Number of pages
7
Pages from-to
41
UT code for WoS article
000616056800001
EID of the result in the Scopus database
2-s2.0-85100217534