In situ assessment of the renal microcirculation in mechanically ventilated rats using sidestream dark-field imaging
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11150%2F15%3A10284231" target="_blank" >RIV/00216208:11150/15:10284231 - isvavai.cz</a>
Alternative codes found
RIV/00179906:_____/15:10284231 RIV/00843989:_____/15:E0104823
Result on the web
<a href="http://onlinelibrary.wiley.com.ezproxy.is.cuni.cz/doi/10.1111/jmi.12198/epdf" target="_blank" >http://onlinelibrary.wiley.com.ezproxy.is.cuni.cz/doi/10.1111/jmi.12198/epdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1111/jmi.12198" target="_blank" >10.1111/jmi.12198</a>
Alternative languages
Result language
angličtina
Original language name
In situ assessment of the renal microcirculation in mechanically ventilated rats using sidestream dark-field imaging
Original language description
For microcirculation research there is a need for baseline data and feasibility protocols describing microcirculation of various organs. The aim of our study was to examine the reliability and reproducibility of sidestream dark-field (SDF) imaging withinthe renal cortical microcirculation in rats. Renal microcirculation was observed using SDF probe placed on the exposed renal surface via the upper midline laparotomy. Video sequences recorded intermittently in short apneic pauses were analyzed off-lineby using AVA 3.0 software (MicroVision Medical, Amsterdam, the Netherlands). Results are expressed as mean (SD) or median (25-75% percentiles). We obtained 60 clear sequences from all recorded analyzable videos from all the animals. The total small vessel and all vessel density (in mm.mm(-2) ) were (28.79 +- 0.40) and (28.95 +- 0.40), respectively. The perfused small and all vessel density were (28.79 +- 0.40) and (28.95 +- 0.40), respectively. The DeBacker Score was (19.14 +- 0.43), the
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
FE - Other fields of internal medicine
OECD FORD branch
—
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2015
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Microscopy
ISSN
0022-2720
e-ISSN
—
Volume of the periodical
257
Issue of the periodical within the volume
2
Country of publishing house
GB - UNITED KINGDOM
Number of pages
5
Pages from-to
161-165
UT code for WoS article
000347382100009
EID of the result in the Scopus database
2-s2.0-84920272543