A comparison of three rubber dam systems in vivo - A preliminary study
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11150%2F15%3A10313700" target="_blank" >RIV/00216208:11150/15:10313700 - isvavai.cz</a>
Alternative codes found
RIV/00179906:_____/15:10313700
Result on the web
<a href="http://dx.doi.org/10.14712/18059694.2015.86" target="_blank" >http://dx.doi.org/10.14712/18059694.2015.86</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.14712/18059694.2015.86" target="_blank" >10.14712/18059694.2015.86</a>
Alternative languages
Result language
angličtina
Original language name
A comparison of three rubber dam systems in vivo - A preliminary study
Original language description
The aim of this study was to compare the isolation systems OptraDam(R) Plus and OptiDamTM with the conventional rubber dam in terms of objective and subjective parameters. The isolation systems were applied during the dental treatment of the patients. The time of preparation, placement, presence and removal were measured and the quality of isolation was evaluated. The median time of rubber dam placement was 76 s (Q1=62 s; Q3=111.25 s). The application time of OptraDam(R) Plus was significantly longer compared to the other systems (P<0.001). The median volume of fluid remaining in the isolated space after 5 minutes was 4.9 mL (Q1=4 mL; Q3=5 mL). The differences between the systems with regards to isolation quality were not statistically significant. Themajority of the patients reported a higher level of comfort during the treatment with a rubber dam than without it. The attitude of patients was not affected by any of the observed factors. The ranking of the isolation systems according
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
FF - ENT (ie. ear, nose, throat), ophthalmology, dentistry
OECD FORD branch
—
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2015
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Acta Medica (Hradec Králové)
ISSN
1211-4286
e-ISSN
—
Volume of the periodical
58
Issue of the periodical within the volume
1
Country of publishing house
CZ - CZECH REPUBLIC
Number of pages
6
Pages from-to
15-20
UT code for WoS article
—
EID of the result in the Scopus database
2-s2.0-84953408330