Sleep Apnea Detection with Polysomnography and Depth Sensors
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11150%2F20%3A10418376" target="_blank" >RIV/00216208:11150/20:10418376 - isvavai.cz</a>
Alternative codes found
RIV/68407700:21730/20:00347296 RIV/00179906:_____/20:10418376 RIV/60461373:22340/20:43920948
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=0D_xPG56Ns" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=0D_xPG56Ns</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/s20051360" target="_blank" >10.3390/s20051360</a>
Alternative languages
Result language
angličtina
Original language name
Sleep Apnea Detection with Polysomnography and Depth Sensors
Original language description
This paper is devoted to proving two goals, to show that various depth sensors can be used to record breathing rate with the same accuracy as contact sensors used in polysomnography (PSG), in addition to proving that breathing signals from depth sensors have the same sensitivity to breathing changes as in PSG records. The breathing signal from depth sensors can be used for classification of sleep apnea events with the same success rate as with PSG data. The recent development of computational technologies has led to a big leap in the usability of range imaging sensors. New depth sensors are smaller, have a higher sampling rate, with better resolution, and have bigger precision. They are widely used for computer vision in robotics, but they can be used as non-contact and non-invasive systems for monitoring breathing and its features. The breathing rate can be easily represented as the frequency of a recorded signal. All tested depth sensors (MS Kinect v2, RealSense SR300, R200, D415 and D435) are capable of recording depth data with enough precision in depth sensing and sampling frequency in time (20-35 frames per second (FPS)) to capture breathing rate. The spectral analysis shows a breathing rate between 0.2 Hz and 0.33 Hz, which corresponds to the breathing rate of an adult person during sleep. To test the quality of breathing signal processed by the proposed workflow, a neural network classifier (simple competitive NN) was trained on a set of 57 whole night polysomnographic records with a classification of sleep apneas by a sleep specialist. The resulting classifier can mark all apnea events with 100% accuracy when compared to the classification of a sleep specialist, which is useful to estimate the number of events per hour. When compared to the classification of polysomnographic breathing signal segments by a sleep specialist, which is used for calculating length of the event, the classifier has an F-1 score of 92.2% Accuracy of 96.8% (sensitivity 89.1% and specificity 98.8%). The classifier also proves successful when tested on breathing signals from MS Kinect v2 and RealSense R200 with simulated sleep apnea events. The whole process can be fully automatic after implementation of automatic chest area segmentation of depth data.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30502 - Other medical science
Result continuities
Project
<a href="/en/project/EF17_048%2F0007441" target="_blank" >EF17_048/0007441: PERSONMED - Center for the Development of Personalized Medicine in Age-Related Diseases</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2020
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Sensors
ISSN
1424-8220
e-ISSN
—
Volume of the periodical
20
Issue of the periodical within the volume
5
Country of publishing house
CH - SWITZERLAND
Number of pages
11
Pages from-to
1360
UT code for WoS article
000525271500122
EID of the result in the Scopus database
2-s2.0-85080981213