All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Long-term safety and efficacy of distal aneurysm treatment with flow diversion in the M2 segment of the middle cerebral artery and beyond

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11150%2F21%3A10422410" target="_blank" >RIV/00216208:11150/21:10422410 - isvavai.cz</a>

  • Alternative codes found

    RIV/00159816:_____/21:00073541 RIV/00216224:14110/21:00121122

  • Result on the web

    <a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=IqjdjeG5Ck" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=IqjdjeG5Ck</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1136/neurintsurg-2020-016790" target="_blank" >10.1136/neurintsurg-2020-016790</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Long-term safety and efficacy of distal aneurysm treatment with flow diversion in the M2 segment of the middle cerebral artery and beyond

  • Original language description

    Background: Indications for flow diversion stent (FDS) treatment are expanding. However, there is still a lack of evidence for the long-term outcome in distally located aneurysms in the M2 segment of the middle cerebral artery (MCA) and beyond. Methods: Consecutive subjects (from June 2013 to August 2020) with MCA aneurysms in the M2 segment or beyond treated with FDS were reviewed retrospectively. The primary endpoints for clinical safety were the absence of mortality, stroke event, re-rupture of the aneurysm, and worsening of clinical symptoms. The primary endpoint for treatment efficacy was complete/near-complete occlusion at follow-up after 12 months. Results: 23 patients were identified: 7 aneurysms were located in the M2 segment of the MCA, 4 in the M2-M3 bifurcation, 2 in M3, 3 in M3-4 branching, and 2 in M4; 5 aneurysms were located in M2 with extension into the M1-M2 bifurcation. 13 aneurysms were of fusiform morphology, 8 sacculofusiform, and 2 saccular. 16 aneurysms were of highly suspected dissecting etiology. The median diameter of the parent vessel was 2.1 mm proximally and 2 mm distally. The median time of the follow-up was 30 months (range 16 months to 6 years). Complete/near complete occlusion was observed in 14/20 patients (70%) and one stable remodeling (5%) was seen at 12 months. 22 patients (95.6%) had an excellent clinical outcome (mRS 0-1) at 6 months. Technical challenges associated with the deployment of FDS occurred in 8.7% of cases. Severe complications, intraparenchymal hemorrhage and re-rupture of the aneurysm occurred in 2 patients (8.7%). Conclusion: Flow diversion of distally located aneurysms is technically feasible with low morbidity and mortality.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    30224 - Radiology, nuclear medicine and medical imaging

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2021

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Journal of NeuroInterventional Surgery

  • ISSN

    1759-8478

  • e-ISSN

  • Volume of the periodical

    13

  • Issue of the periodical within the volume

    7

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    6

  • Pages from-to

    631-636

  • UT code for WoS article

    000667295800013

  • EID of the result in the Scopus database

    2-s2.0-85094179850