Influence of the Manufacturing Process on the Corrosion and Mechanical Behavior of Esophageal Stents
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11150%2F23%3A10469585" target="_blank" >RIV/00216208:11150/23:10469585 - isvavai.cz</a>
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=5IigpHg~gC" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=5IigpHg~gC</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/met13091542" target="_blank" >10.3390/met13091542</a>
Alternative languages
Result language
angličtina
Original language name
Influence of the Manufacturing Process on the Corrosion and Mechanical Behavior of Esophageal Stents
Original language description
Esophageal nitinol stents are an established method for treating swallowing difficulties caused by obstructing cancer. This raesearch investigates the influence of different qualities of raw metal alloys in combination with production technology on corrosion resistance in standardized simulated gastric fluid (SGF). Four different international stent manufacturers produced samples of their standard stents from nitinol sourced from three different alloy manufacturers. The stents were subjected to a 6-week immersion in SGF. During the immersion, the surface was studied at specified intervals using microscopy. The surface of the samples was also studied by X-ray Photoelectron Spectroscopy and after immersion the released ions were analyzed. Results demonstrated that both raw material and certain steps in the manufacturing process negatively affect corrosion resistance. Analysis of the SGF showed that the amount of nickel released is proportional to the degree of corrosion attack. Finally, current accepted standard test methods are inadequate for assessing susceptibility to corrosion by gastric acid and should take the low pH of the implanted environment into account. Conversely, certain measures in the manufacturing process are able to reduce the impact of the base material on corrosion susceptibility.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10610 - Biophysics
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2023
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Metals
ISSN
2075-4701
e-ISSN
2075-4701
Volume of the periodical
13
Issue of the periodical within the volume
9
Country of publishing house
CH - SWITZERLAND
Number of pages
15
Pages from-to
1542
UT code for WoS article
001075948600001
EID of the result in the Scopus database
2-s2.0-85172779842