Bicuspid valve repair outcomes are improved with reduction and stabilization of sinotubular junction and annulus with external annuloplasty
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11150%2F24%3A10482343" target="_blank" >RIV/00216208:11150/24:10482343 - isvavai.cz</a>
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=VQ_ribQV0W" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=VQ_ribQV0W</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jtcvs.2022.11.021" target="_blank" >10.1016/j.jtcvs.2022.11.021</a>
Alternative languages
Result language
angličtina
Original language name
Bicuspid valve repair outcomes are improved with reduction and stabilization of sinotubular junction and annulus with external annuloplasty
Original language description
Objective: We investigated long-term outcomes of bicuspid aortic valve (BAV) repair, with external annuloplasty, according to aorta phenotype. Methods: Between 2003 and 2020, all patients with BAV operated on for aortic insufficiency (AI) and/or aneurysm were included. Repairs included isolated AI repair with subvalvular with or without sinotubular junction (STJ) (single or double) annuloplasty, supracoronary aorta replacement (with or without hemiroot remodeling), and root remodeling with external subvalvular ring annuloplasty. Results: Among 343 patients operated, reparability rate was 81.3% (n = 279; age 46 +/- 13.3 years). At 10 years (median follow-up: 3.42 years; interquartile range, 1.1, 5.8), survival was 93.9% (n = 8 deaths, similar to general population), cumulative incidence of reoperation was 6.2% (n = 10), AI grade >2 was 5.8% (n = 9), and grade >1 was 23.0% (n = 30). BAV repair stabilizing both the annulus and STJ with annuloplasty, compared with nonstabilized STJ repair (single annuloplasty), had lower incidence of reoperation (2.6% vs 22.5%, P = .0018) and AI grade >2 (1.2% vs 23.6%, P < .001) at 9 years. Initial commissural angle <160 degrees was not a risk factor for reoperation, compared with angle >= 160 degrees if symmetrical repair was achieved (2.7% and 4.1%, respectively, at 6 years, P = .85). Multivariable model showed that absence of STJ stabilization (odds ratio, 6.7; 95% confidence interval, 2.1-20, P = .001) increased recurrent AI, but not initial commissural angle <160 degrees (odds ratio, 1.01; 95% confidence interval, 0.39-2.63, P = .98). Commissures adjusted symmetrically led to lower transvalvular gradient, compared with nonsymmetrical repair (8.7 mm Hg vs 10.2 mm Hg, P = .029). Conclusions: BAV repair, tailored to aorta phenotype, is associated with excellent durable outcomes if both annulus and STJ are reduced and stabilized with external ring annuloplasty. Commissural angle <160 degrees is not associated with reoperation if symmetrical repair is achieved.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30201 - Cardiac and Cardiovascular systems
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2024
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
The Journal of Thoracic and Cardiovascular Surgery
ISSN
0022-5223
e-ISSN
1097-685X
Volume of the periodical
168
Issue of the periodical within the volume
1
Country of publishing house
US - UNITED STATES
Number of pages
20
Pages from-to
—
UT code for WoS article
001265008600001
EID of the result in the Scopus database
2-s2.0-85144754143