All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Sequential injection determination of orthophosphate as ion associate of 12-molybdophosphate with Astra Phloxine

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11160%2F11%3A10100197" target="_blank" >RIV/00216208:11160/11:10100197 - isvavai.cz</a>

  • Result on the web

    <a href="http://www.sciencedirect.com/science/article/pii/S0039914011001998" target="_blank" >http://www.sciencedirect.com/science/article/pii/S0039914011001998</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.talanta.2011.02.046" target="_blank" >10.1016/j.talanta.2011.02.046</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Sequential injection determination of orthophosphate as ion associate of 12-molybdophosphate with Astra Phloxine

  • Original language description

    A simple and fast reaction between 12-molybdophosphate heteropoly anion and the polymethine dye Astra Phloxine was used for the development of a new SIA method for the determination of orthophosphate. The suggested method has higher sensitivity and a broader calibration range than existing SIA methods. It can be used to detect phosphate in the range from 0.2 to 10 mu mol L(-1) with a detection limit of 0.1 mu mol L(-1) and an acceptable throughput of 20 samples h(-1). The comparably low molybdate (5.6 mmol L(-1)) and dye (0.1 mmol L(-1)) concentrations led to an improvement in the stability of the base line. Inter-day reproducibility was better than 5%, while the intra-day RSD was in the range 0.8-3.5%. The method was used for the analysis of natural water samples and phosphorus-containing chemicals having a low content of orthophosphate.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    FR - Pharmacology and apothecary chemistry

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    Z - Vyzkumny zamer (s odkazem do CEZ)

Others

  • Publication year

    2011

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Talanta

  • ISSN

    0039-9140

  • e-ISSN

  • Volume of the periodical

    84

  • Issue of the periodical within the volume

    5

  • Country of publishing house

    NL - THE KINGDOM OF THE NETHERLANDS

  • Number of pages

    6

  • Pages from-to

    1355-1360

  • UT code for WoS article

    000292475600027

  • EID of the result in the Scopus database