Determination of effective mobilities of EOF markers in BGE containing sulfated ?-cyclodextrin by a two-detector method
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F13%3A10133670" target="_blank" >RIV/00216208:11310/13:10133670 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.1002/elps.201200490" target="_blank" >http://dx.doi.org/10.1002/elps.201200490</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/elps.201200490" target="_blank" >10.1002/elps.201200490</a>
Alternative languages
Result language
angličtina
Original language name
Determination of effective mobilities of EOF markers in BGE containing sulfated ?-cyclodextrin by a two-detector method
Original language description
A neutral marker of the EOF can gain a nonzero effective mobility because of its possible interaction with a charged complexing agent, such as a chiral selector in CE. We determined effective mobilities of four compounds often used as EOF markers (dimethyl sulfoxide,mesityl oxide, nitromethane, and thiourea) in the BGE-containing sulfated -CD (60 g/L). All the compounds studied were measurably mobilized by their interaction with the selector. The highest effectivemobility (-3.0.10MINUS SIGN 9m2sMINUS SIGN 1VMINUS SIGN 1) was observed for thiourea and the lowest (-1.5.10MINUS SIGN 9m2sMINUS SIGN 1VMINUS SIGN 1) for dimethyl sulfoxide and nitromethane. The mobilities were determined by a new two-detector pressure mobilization method (2d method), which wepropose, and the results were confirmed by standard CE measurements. In the 2d method, one marker zone is situated in the BGE containing the charged selector, while the second marker zone is surrounded with a selector-free BGE, which pre
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
CB - Analytical chemistry, separation
OECD FORD branch
—
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2013
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Electrophoresis
ISSN
0173-0835
e-ISSN
—
Volume of the periodical
34
Issue of the periodical within the volume
5
Country of publishing house
GB - UNITED KINGDOM
Number of pages
9
Pages from-to
768-776
UT code for WoS article
000316267100019
EID of the result in the Scopus database
—