Ultratrace determination of tin by hydride generation in-atomizer trapping atomic absorption spectrometry
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F13%3A10174176" target="_blank" >RIV/00216208:11310/13:10174176 - isvavai.cz</a>
Alternative codes found
RIV/68081715:_____/13:00398565
Result on the web
<a href="http://dx.doi.org/10.1016/j.aca.2013.10.015" target="_blank" >http://dx.doi.org/10.1016/j.aca.2013.10.015</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.aca.2013.10.015" target="_blank" >10.1016/j.aca.2013.10.015</a>
Alternative languages
Result language
angličtina
Original language name
Ultratrace determination of tin by hydride generation in-atomizer trapping atomic absorption spectrometry
Original language description
A quartz multiatomizer with its inlet arm modified to serve as a trap (trap-and-atomizer device) was employed to trap tin hydride and subsequently to volatilize collected analyte species with atomic absorption spectrometric detection. Generation, atomization and preconcentration conditions were optimized and analytical figures of merit of both on-line atomization as well as preconcentration modes were quantified. Preconcentration efficiency of 95 +/- 5% was found. The detection limits reached were 0.029and 0.14 ng mL(-1) Sn, respectively, for 120 s preconcentration period and on-line atomization mode without any preconcentration. The interference extent of other hydride forming elements (As, Se, Sb and Bi) on tin determination was found negligible inboth modes of operation. The applicability of the developed preconcentration method was verified by Sn determination in a certified reference material as well as by analysis of real samples. (C) 2013 Elsevier B.V. All rights reserved.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
CB - Analytical chemistry, separation
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/GPP206%2F11%2FP002" target="_blank" >GPP206/11/P002: Quartz trap for ultratrace determination of lead and tin ? optimization, detector comparison and mechanistic study</a><br>
Continuities
Z - Vyzkumny zamer (s odkazem do CEZ)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2013
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Analytica Chimica Acta
ISSN
0003-2670
e-ISSN
—
Volume of the periodical
804
Issue of the periodical within the volume
December
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
9
Pages from-to
50-58
UT code for WoS article
000327493500005