Voltammetric Determination of Nitrofurantoin at a Mercury Meniscus Modified Silver Solid Amalgam Electrode
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F15%3A10291006" target="_blank" >RIV/00216208:11310/15:10291006 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.1002/elan.201400410" target="_blank" >http://dx.doi.org/10.1002/elan.201400410</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/elan.201400410" target="_blank" >10.1002/elan.201400410</a>
Alternative languages
Result language
angličtina
Original language name
Voltammetric Determination of Nitrofurantoin at a Mercury Meniscus Modified Silver Solid Amalgam Electrode
Original language description
Electrochemical behavior of nitrofurantoin (NF) was studied by direct current voltammetry (DCV), differential pulse voltammetry (DPV), and cyclic voltammetry (CV) using a mercury meniscus modified silver solid amalgam electrode (m-AgSAE). Voltammetric behavior of NF was studied in cathodic region of potentials in dependence on pH. pH 7.0 was selected as an optimal medium for the determination of NF by both DCV and DPV, with the optimal methanol-water volume ratio of 1 : 9. In order to reduce the negative influence of electrode passivation, the suitable regeneration potentials were found (0 mV and -900 mV). The optimal conditions were found for the determination of NF in concentration ranges from 6 x 10(-6) mol L-1 to 1 x 10(-4) mol L-1 using DCV technique, and from 2 x 10(-7) mol L-1 to 1 x 10(-4) mol L-1 using DPV technique, both in the medium of methanol-Britton-Robinson buffer pH 7.0 (1 : 9). The attained limit of quantification (LOQ) of NF was 1.6 x 10(-6) mol L-1 for DCV and 8.1 x
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
CG - Electrochemistry
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/GBP206%2F12%2FG151" target="_blank" >GBP206/12/G151: Center of novel approaches to bioanalysis and molecular diagnostics</a><br>
Continuities
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2015
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Electroanalysis
ISSN
1040-0397
e-ISSN
—
Volume of the periodical
27
Issue of the periodical within the volume
1
Country of publishing house
DE - GERMANY
Number of pages
8
Pages from-to
185-192
UT code for WoS article
000347838300022
EID of the result in the Scopus database
2-s2.0-84920944860