Evaluation of portable Raman instruments with 532 and 785-nm excitation for identification of zeolites and beryllium containing silicates
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F15%3A10313116" target="_blank" >RIV/00216208:11310/15:10313116 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.1002/jrs.4732" target="_blank" >http://dx.doi.org/10.1002/jrs.4732</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/jrs.4732" target="_blank" >10.1002/jrs.4732</a>
Alternative languages
Result language
angličtina
Original language name
Evaluation of portable Raman instruments with 532 and 785-nm excitation for identification of zeolites and beryllium containing silicates
Original language description
In this short paper we present Raman spectra of minerals of the group of zeolites and beryllium containing silicates (thomsonite, stilbite, natrolite, euclase, phenakite, bavenite, milarite and beryl) obtained indoors/outdoors on a collection of samplesusing a portable 532-nm/785-nm systems. This study complements a previous one in which one of the first handheld 785-nm excitation instruments was tested. To our knowledge this is the first time that a handheld Raman spectrometer equipped with a 532-nm laser as well as a portable dual instrument with 532/785-nm excitation was used in mineralogy. For the major findings of the zeolites investigated, the most intense Raman bands are found at correct positions +/-2-4cm(-1). Although acceptable results wereobtained using the 532-nm excitations with both the instruments (the strongest bands are well developed and these bands permit the unambiguous identification), the use of the near-infrared excitation can especially be recommended (higher
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
CA - Inorganic chemistry
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/GAP210%2F10%2F0467" target="_blank" >GAP210/10/0467: Detection of Exobiological Markers Using Raman Spectroscopy as a Key Method</a><br>
Continuities
Z - Vyzkumny zamer (s odkazem do CEZ)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2015
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Raman Spectroscopy
ISSN
0377-0486
e-ISSN
—
Volume of the periodical
46
Issue of the periodical within the volume
10
Country of publishing house
GB - UNITED KINGDOM
Number of pages
6
Pages from-to
927-932
UT code for WoS article
000363090200015
EID of the result in the Scopus database
2-s2.0-84944155224