Determination of relative enantiomer migration order using a racemic sample

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F15%3A10315456" target="_blank" >RIV/00216208:11310/15:10315456 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1016/j.chroma.2015.10.058" target="_blank" >http://dx.doi.org/10.1016/j.chroma.2015.10.058</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.chroma.2015.10.058" target="_blank" >10.1016/j.chroma.2015.10.058</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Determination of relative enantiomer migration order using a racemic sample

  • Original language description

    We developed a method that enables us to distinguish between the same or the opposite enantiomer migration order (EMO) of two enantiomers of a chiral compound with two different selectors. The method is applicable to racemic samples and thus a standard of the pure enantiomeric form(s) is not required. First, complexation constants and mobilities of complexes of the two enantiomers with the first and second selector are determined. However, for a racemic sample it is not possible to deduce whether the first migrating enantiomer with one selector is the same one as the first migrating enantiomer with the second selector. A specific mixture of the two selectors is designed to resolve this. In case the two enantiomers exhibit the same, respectively the opposite EMO in the two selectors, the mixture does, respectively does not separate the racemic sample. Thus two peaks are detected in the first case, while a single coalescent peak is recorded in the opposite case. We demonstrate the method

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    CB - Analytical chemistry, separation

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/GJ15-18424Y" target="_blank" >GJ15-18424Y: New generation of software and development of advanced theory of electromigration in electrokinetic chromatography</a><br>

  • Continuities

    S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2015

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Journal of Chromatography A

  • ISSN

    0021-9673

  • e-ISSN

  • Volume of the periodical

    1424

  • Issue of the periodical within the volume

    neuveden

  • Country of publishing house

    NL - THE KINGDOM OF THE NETHERLANDS

  • Number of pages

    5

  • Pages from-to

    139-143

  • UT code for WoS article

    000366772800017

  • EID of the result in the Scopus database

    2-s2.0-84948753058