All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Pressure-assisted introduction of urine samples into a short capillary for electrophoretic separation with contactless conductivity and UV spectrometry detection

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F15%3A10318293" target="_blank" >RIV/00216208:11310/15:10318293 - isvavai.cz</a>

  • Alternative codes found

    RIV/00216208:11120/15:43909817

  • Result on the web

    <a href="http://dx.doi.org/10.1002/elps.201400613" target="_blank" >http://dx.doi.org/10.1002/elps.201400613</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1002/elps.201400613" target="_blank" >10.1002/elps.201400613</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Pressure-assisted introduction of urine samples into a short capillary for electrophoretic separation with contactless conductivity and UV spectrometry detection

  • Original language description

    A computer-controlled hydrodynamic sample introduction method has been proposed for short-capillary electrophoresis. In the method, the BGE flushes sample from the loop of a six-way sampling valve and is carried to the injection end of the capillary. A short pressure impulse is generated in the electrolyte stream at the time when the sample zone is at the capillary, leading to injection of the sample into the capillary. Then the electrolyte flow is stopped and the separation voltage is turned on. This way of sample introduction does not involve movement of the capillary and both of its ends remain constantly in the solution during both sample injection and separation. The amount of sample introduced to the capillary is controlled by the duration of thepressure pulse. The new sample introduction method was tested in the determination of ammonia, creatinine, uric acid, and hippuric acid in human urine. The determination was performed in a capillary with an overall length of 10.5 cm, in

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    CB - Analytical chemistry, separation

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2015

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Electrophoresis

  • ISSN

    0173-0835

  • e-ISSN

  • Volume of the periodical

    36

  • Issue of the periodical within the volume

    16

  • Country of publishing house

    DE - GERMANY

  • Number of pages

    7

  • Pages from-to

    1962-1968

  • UT code for WoS article

    000360055300023

  • EID of the result in the Scopus database

    2-s2.0-84939467093