Novel designs of dielectric barrier discharge hydride atomizers for atomic spectrometry
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F18%3A10378571" target="_blank" >RIV/00216208:11310/18:10378571 - isvavai.cz</a>
Result on the web
<a href="https://doi.org/10.1016/j.sab.2018.05.006" target="_blank" >https://doi.org/10.1016/j.sab.2018.05.006</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.sab.2018.05.006" target="_blank" >10.1016/j.sab.2018.05.006</a>
Alternative languages
Result language
angličtina
Original language name
Novel designs of dielectric barrier discharge hydride atomizers for atomic spectrometry
Original language description
Eight designs of dielectric barrier discharge (DBD) atomizers have been constructed and optimized. Subsequently, their performance with atomic absorption (AAS), atomic fluorescence (AFS) and atomic emission (AES) detectors was investigated employing arsane as a model analyte. Although being all based on a planar shaped quartz body, the individual DBD designs differed from each other in the style of electrode attachment, electrode shape and area as well as electrode distance. All the designs studied were found compatible with MS detection giving comparable sensitivity (between 0.38 and 0.47 s ng(-1) As) and detection limit (around 0.2 ng ml(-1) As) under optimum atomization conditions. However, significant differences in optimum conditions were found among the designs in terms of the applied voltage that strongly depends on the style of electrode attachment and electrode distance. The design with metal strip electrodes glued to a quartz body requires >14 kV to be operated. The design with sputtered electrodes of the same shape can reach the same sensitivity with 8.5 kV. These values can be further reduced to 6.5 kV, when decreasing the electrode distance from 3 to 1 mm. Selected DBD designs tested have been proven to be compatible with other spectrometric detectors such as AFS reaching detection limit 0.05 ng ml(-1) As or AES with detection limit of 30 ng ml(-1) As showing the universality of the planar DBD designs and its potential to further applications as well as mechanistic studies.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10406 - Analytical chemistry
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2018
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Spectrochimica Acta - Part B: Atomic Spectroscopy
ISSN
0584-8547
e-ISSN
—
Volume of the periodical
146
Issue of the periodical within the volume
August
Country of publishing house
GB - UNITED KINGDOM
Number of pages
8
Pages from-to
69-76
UT code for WoS article
000439675300010
EID of the result in the Scopus database
2-s2.0-85047000509