All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Fast and Sensitive Screening of Oxandrolone and Its Major Metabolite 17-Epi-Oxandrolone in Human Urine by UHPLC-MS/MS with On-Line SPE Sample Pretreatment

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F21%3A10423371" target="_blank" >RIV/00216208:11310/21:10423371 - isvavai.cz</a>

  • Result on the web

    <a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=n6DUQJa6K0" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=n6DUQJa6K0</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.3390/molecules26020480" target="_blank" >10.3390/molecules26020480</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Fast and Sensitive Screening of Oxandrolone and Its Major Metabolite 17-Epi-Oxandrolone in Human Urine by UHPLC-MS/MS with On-Line SPE Sample Pretreatment

  • Original language description

    Oxandrolone, a synthetic testosterone analog, is used for the treatment of several diseases associated with weight loss. Unfortunately, oxandrolone is abused by many athletes and bodybuilders due to its strong anabolic effect. We have developed and validated a highly sensitive and rapid on-line SPE-UHPLC-MS/MS method for the determination of oxandrolone and simultaneous identification of its major metabolite 17-epi-oxandrolone in urine matrices. Enrichment of the analytes via an integrated solid-phase extraction was achieved using an Acquity UPLC BEH C18 Column. Subsequently, the chromatographic separation of the on-line preconcentrated sample fraction was achieved using an Acquity HSS T3 C18 Column. For the structural identification of these analytes, a high-resolution mass spectrometer Synapt-G2Si coupled to the Acquity M-class nano-LC system with ionKey source was used. A highly sensitive determination of oxandrolone was achieved using a tandem quadrupole mass spectrometer XEVO TQD. The method was successfully validated in the linear range of oxandrolone from 81.63 pg center dot mL(-1) (limit of quantification, LOQ) to 5000 pg center dot mL(-1) in the human urine matrix. It was applied to the analysis of real urine samples obtained from a healthy volunteer after the oral administration of one dose (10 mg) of oxandrolone. Concentration vs. time dependence was tested in the time interval of 4 h-12 days (after oral administration) to demonstrate the ability of the method to detect the renal elimination of oxandrolone from the human body. Favorable performance parameters along with successful application indicate the usefulness of the proposed method for its routine use in antidoping control labs.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10406 - Analytical chemistry

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2021

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Molecules

  • ISSN

    1420-3049

  • e-ISSN

  • Volume of the periodical

    26

  • Issue of the periodical within the volume

    2

  • Country of publishing house

    CH - SWITZERLAND

  • Number of pages

    15

  • Pages from-to

    480

  • UT code for WoS article

    000611441700001

  • EID of the result in the Scopus database

    2-s2.0-85100327552