A new approach for discriminating spatially acquired SERS spectra using antiretroviral drug emtricitabine as a test sample
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F24%3A10490005" target="_blank" >RIV/00216208:11310/24:10490005 - isvavai.cz</a>
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=Zaykfl_FSB" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=Zaykfl_FSB</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/jrs.6721" target="_blank" >10.1002/jrs.6721</a>
Alternative languages
Result language
angličtina
Original language name
A new approach for discriminating spatially acquired SERS spectra using antiretroviral drug emtricitabine as a test sample
Original language description
In this study, an antiretroviral drug emtricitabine (also known as FTC or Emtriva) was detected and quantified down to 40 ng/ml by using surface-enhanced Raman spectroscopy (SERS). Its aqueous standards were tested with two types of silver nanoparticles (colloidal and dendritic) using a specially developed aluminum well plate. The SERS spectra were acquired using a Raman scanning device with 30-mu m spatial resolution. The spectral data were analyzed using a new approach for the discrimination of the spatially acquired spectra based on the Quality index (Qi). After the Qi is calculated, the spectral data are sorted based on the Qi. This is followed by selecting only the spectra with a high Qi index and comparing the average of all the spatially acquired spectra. This results in an improvement in the spectral signal-to-noise and higher analytical sensitivity of the built calibration curves. Spatially discrimination: improvement of the analytical sensitivity was accomplished by using spatial discrimination and comparing the averaging of all the acquired spectra to spatial discrimination followed by averaging. In this study, the quantification method for the antiretroviral drug emtricitabine (FTC or Emtriva (R)) at clinically relevant concentrations was reached. Two different types of silver nanoparticles were tested, colloidal and dendritic, and deposited on the aluminum well plate, which was placed in the automated Raman scanning device. image
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10403 - Physical chemistry
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2024
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Raman Spectroscopy
ISSN
0377-0486
e-ISSN
1097-4555
Volume of the periodical
55
Issue of the periodical within the volume
11
Country of publishing house
GB - UNITED KINGDOM
Number of pages
10
Pages from-to
1129-1138
UT code for WoS article
001279462000001
EID of the result in the Scopus database
2-s2.0-85200003858