Fatigue endurance of Ti-6Al-4V alloy with electro-eroded surface forimproved bone in-growth
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11320%2F11%3A10107758" target="_blank" >RIV/00216208:11320/11:10107758 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.1016/j.jmbbm.2010.12.001" target="_blank" >http://dx.doi.org/10.1016/j.jmbbm.2010.12.001</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jmbbm.2010.12.001" target="_blank" >10.1016/j.jmbbm.2010.12.001</a>
Alternative languages
Result language
angličtina
Original language name
Fatigue endurance of Ti-6Al-4V alloy with electro-eroded surface forimproved bone in-growth
Original language description
Ti-6Al-4V hour-glass shaped rotating beam specimens with duplex microstructure were processed by electric discharge machining (EDM). A comparatively high peak current of 29A was utilized in order to increase surface roughness for improved osteointegration. High cycle fatigue (HCF) tests were performed in rotating beam loading (R = -1) on these EDM specimens and results were compared with electrolytically polished specimens serving as reference. As expected, the HCF performance of EDM specimens was inferior to the electrolytically polished specimens. A detailed study of fatigue crack nucleation and microcrack growth was carried out on failed specimens by SEM. The poor HCF strength of EDM specimens is explained by early crack nucleation due to the high notch sensitivity of Ti-6Al-4V. In addition, process-induced residual tensile stresses and microstructural effects may also account for the drastic loss in HCF performance relative to the electropolished baseline. (C) 2010 Elsevier Ltd. Al
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
BM - Solid-state physics and magnetism
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/ME09012" target="_blank" >ME09012: Stability of metastable Beta-Ti Alloys</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Others
Publication year
2011
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of the Mechanical Behavior of Biomedical Materials
ISSN
1751-6161
e-ISSN
—
Volume of the periodical
4
Issue of the periodical within the volume
3
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
6
Pages from-to
417-422
UT code for WoS article
000288236300021