All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Calibration and Alignment Framework for the Belle II detector

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11320%2F18%3A10389757" target="_blank" >RIV/00216208:11320/18:10389757 - isvavai.cz</a>

  • Result on the web

    <a href="http://iopscience.iop.org/article/10.1088/1742-6596/1085/3/032023/meta" target="_blank" >http://iopscience.iop.org/article/10.1088/1742-6596/1085/3/032023/meta</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1088/1742-6596/1085/3/032023" target="_blank" >10.1088/1742-6596/1085/3/032023</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Calibration and Alignment Framework for the Belle II detector

  • Original language description

    The Belle II experiment is approaching its first physics run in 2018. Its full capability to operate at the precision frontier will need not only excellent performance of the SuperKEKB accelerator and the detector, but also advanced calibration methods combined with data quality monitoring. To deliver data in a form suitable for analysis as soon as possible, an automated Calibration Framework (CAF) has been developed. The CAF integrates various calibration algorithms and their input collection methods for event-level data. It allows execution of the calibration workflow using different backends from local machines to a computing cluster, resolution of dependencies among algorithms, management of the produced calibration constants, and database access across possible iterations. One of the main algorithms fully integrated in the framework uses Millepede II [2] to solve a large minimization problem emerging in the track-based alignment and calibration of the pixel and strip detector, the central drift chamber, and the muon system. Advanced fitting tools are used to properly describe the detector material and magnetic field and include measurements of different sub-detectors into a single global fit performed by Millepede. This talk will present the design of the calibration framework, the integration of the Millepede calibration, and its current performance.

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

  • OECD FORD branch

    10303 - Particles and field physics

Result continuities

  • Project

    <a href="/en/project/LTT17020" target="_blank" >LTT17020: Study of Beyond Standard Model Physics with the International Experiment Belle II in Japan</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2018

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    Journal of Physics: Conference Series [online]

  • ISBN

  • ISSN

    1742-6596

  • e-ISSN

    neuvedeno

  • Number of pages

    6

  • Pages from-to

  • Publisher name

    IOP Publishing

  • Place of publication

    UK

  • Event location

    Seattle, Spojené Státy Americké

  • Event date

    Aug 21, 2017

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article