Performance of the ATLAS RPC detector and Level-1 muon barrel trigger at root s=13 TeV
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11320%2F21%3A10440641" target="_blank" >RIV/00216208:11320/21:10440641 - isvavai.cz</a>
Alternative codes found
RIV/68407700:21220/21:00354825 RIV/68407700:21340/21:00354825 RIV/68407700:21670/21:00354825 RIV/61989592:15310/21:73608338
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=iYpSwzJMlN" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=iYpSwzJMlN</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1748-0221/16/07/P07029" target="_blank" >10.1088/1748-0221/16/07/P07029</a>
Alternative languages
Result language
angličtina
Original language name
Performance of the ATLAS RPC detector and Level-1 muon barrel trigger at root s=13 TeV
Original language description
The ATLAS experiment at the Large Hadron Collider (LHC) employs a trigger system consisting of a first-level hardware trigger (L1) and a software-based high-level trigger. The L1 muon trigger system selects muon candidates, assigns them to the correct LHC bunch crossing and classifies them into one of six transverse-momentum threshold classes. The L1 muon trigger system uses resistive-plate chambers (RPCs) to generate the muon-induced trigger signals in the central (barrel) region of the ATLAS detector. The ATLAS RPCs are arranged in six concentric layers and operate in a toroidal magnetic field with a bending power of 1.5 to 5.5 Tm. The RPC detector consists of about 3700 gas volumes with a total surface area of more than 4000 m(2). This paper reports on the performance of the RPC detector and L1 muon barrel trigger using 60.8 fb(-1) of proton-proton collision data recorded by the ATLAS experiment in 2018 at a centre-of-mass energy of 13 TeV. Detector and trigger performance are studied using Z boson decays into a muon pair. Measurements of the RPC detector response, efficiency, and time resolution are reported. Measurements of the L1 muon barrel trigger efficiencies and rates are presented, along with measurements of the properties of the selected sample of muon candidates. Measurements of the RPC currents, counting rates and mean avalanche charge are performed using zero-bias collisions. Finally, RPC detector response and efficiency are studied at different high voltage and front-end discriminator threshold settings in order to extrapolate detector response to the higher luminosity expected for the High Luminosity LHC.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10300 - Physical sciences
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2021
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Instrumentation [online]
ISSN
1748-0221
e-ISSN
—
Volume of the periodical
16
Issue of the periodical within the volume
7
Country of publishing house
GB - UNITED KINGDOM
Number of pages
64
Pages from-to
P07029
UT code for WoS article
000694909000009
EID of the result in the Scopus database
2-s2.0-85112599984