All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

The Silicon Vertex Detector of the Belle II experiment

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11320%2F22%3A10457170" target="_blank" >RIV/00216208:11320/22:10457170 - isvavai.cz</a>

  • Alternative codes found

    RIV/00216208:11320/16:10335272 RIV/00216208:11320/22:10454502 RIV/00216208:11320/23:10475851 RIV/00216208:11320/24:10494182 RIV/00216208:11320/24:10494185

  • Result on the web

    <a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=x3QRE.EJQW" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=x3QRE.EJQW</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.nima.2022.166688" target="_blank" >10.1016/j.nima.2022.166688</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    The Silicon Vertex Detector of the Belle II experiment

  • Original language description

    The Silicon Vertex Detector (SVD) is a part of the vertex detector in the Belle II experiment at the SuperKEKB collider (KEK, Japan). Since the start of data taking in spring 2019, the SVD has been operating stably and reliably with a high signal-to-noise ratio and hit efficiency, achieving good spatial resolution and high track reconstruction efficiency. The hit occupancy, which mostly comes from the beam-related background, is currently about 0.5% in the innermost layer, causing no impact on the SVD performance. In anticipation of the operation at higher luminosity in the following years, two strategies to sustain the tracking performance in future high beam background conditions have been developed and tested on data. One is to reduce the number of signal waveform samples to decrease dead time, data size, and occupancy. The other is to utilize the good hit-time resolution to reject the beam background hits. We also measured the radiation effects on the full depletion voltage, sensor current, and strip noise caused during the first two and a half years of operation. The results show no detrimental effect on the SVD performance.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10300 - Physical sciences

Result continuities

  • Project

    <a href="/en/project/GA22-18469S" target="_blank" >GA22-18469S: Studies of the Beyond Standard Model phenomena in the flavor sector with the Belle II Experiment</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2022

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Nuclear Instruments &amp; Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment

  • ISSN

    0168-9002

  • e-ISSN

    1872-9576

  • Volume of the periodical

    1033

  • Issue of the periodical within the volume

    2022

  • Country of publishing house

    NL - THE KINGDOM OF THE NETHERLANDS

  • Number of pages

    5

  • Pages from-to

    166688

  • UT code for WoS article

    001257091700001

  • EID of the result in the Scopus database

    2-s2.0-85129552019