Performance of the CMS electromagnetic calorimeter in pp collisions at √s=13 TeV
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11320%2F24%3A10493482" target="_blank" >RIV/00216208:11320/24:10493482 - isvavai.cz</a>
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=5EY~.wck11" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=5EY~.wck11</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1748-0221/19/09/P09004" target="_blank" >10.1088/1748-0221/19/09/P09004</a>
Alternative languages
Result language
angličtina
Original language name
Performance of the CMS electromagnetic calorimeter in pp collisions at √s=13 TeV
Original language description
The operation and performance of the Compact Muon Solenoid (CMS) electromagnetic calorimeter (ECAL) are presented, based on data collected in pp collisions at root s = 13 TeV at the CERN LHC, in the years from 2015 to 2018 (LHC Run 2), corresponding to an integrated luminosity of 151 fb(-1). The CMS ECAL is a scintillating lead-tungstate crystal calorimeter, with a silicon strip preshower detector in the forward region that provides precise measurements of the energy and the time-of-arrival of electrons and photons. The successful operation of the ECAL is crucial for a broad range of physics goals, ranging from observing the Higgs boson and measuring its properties, to other standard model measurements and searches for new phenomena. Precise calibration, alignment, and monitoring of the ECAL response are important ingredients to achieve these goals. To face the challenges posed by the higher luminosity, which characterized the operation of the LHC in Run 2, the procedures established during the 2011-2012 run of the LHC have been revisited and new methods have been developed for the energy measurement and for the ECAL calibration. The energy resolution of the calorimeter, for electrons from Z boson decays reaching the ECAL without significant loss of energy by bremsstrahlung, was better than 1.8%, 3.0%, and 4.5% in the vertical bar eta vertical bar intervals [ 0.0, 0.8], [0.8, 1.5], [1.5, 2.5], respectively. This resulting performance is similar to that achieved during Run 1 in 2011-2012, in spite of the more severe running conditions.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10300 - Physical sciences
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2024
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Instrumentation
ISSN
1748-0221
e-ISSN
1748-0221
Volume of the periodical
19
Issue of the periodical within the volume
09
Country of publishing house
GB - UNITED KINGDOM
Number of pages
64
Pages from-to
P09004
UT code for WoS article
001381771700002
EID of the result in the Scopus database
2-s2.0-85204338745