Comparison of two low flow interfaces for measurement of mobilities and stability constants by affinity capillary electrophoresis-mass spectrometry
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11510%2F18%3A10380057" target="_blank" >RIV/00216208:11510/18:10380057 - isvavai.cz</a>
Alternative codes found
RIV/61388963:_____/18:00493561 RIV/00216208:11310/18:10380057
Result on the web
<a href="https://doi.org/10.1016/j.chroma.2018.07.014" target="_blank" >https://doi.org/10.1016/j.chroma.2018.07.014</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.chroma.2018.07.014" target="_blank" >10.1016/j.chroma.2018.07.014</a>
Alternative languages
Result language
angličtina
Original language name
Comparison of two low flow interfaces for measurement of mobilities and stability constants by affinity capillary electrophoresis-mass spectrometry
Original language description
Affinity capillary electrophoresis (ACE) is typically used for the determination of stability constant, K-st, of weak to moderately strong complexes. Sensitive detection such as mass spectrometry (MS) is required for extension of ACE methodology for estimation of K-st of stronger complexes. Consequently, an efficient interface for hyphenation of CE with MS detection is necessary. For evaluation of interfaces for electrospray ionization mass spectrometric (ESI/MS) detection in ACE conditions, potassium-crown ether complexation was used as model system. The effective mobilities of the crown ether ligands and the K-st of their potassium complexes were measured/determined by ACE-ESI/MS using two lab-made interfaces: (i) a sheathless porous tip CE-ESI/MS interface and (ii) a nano-sheath liquid flow CE-ESI/MS interface, and, in turn, compared with those obtained by ACE with UV spectrophotometric detection. Apparent stability constant of potassium-crown ether complexes in 60/40 (v/v) methanol/water mixed solvent, pH* 5.5, was about 1300 L/mol for dibenzo-18-crown-6, 1600 L/mol for benzo-18-crown-6 and 5200 L/mol for 18-crown-6 ligands, respectively. It was observed that electrophoretic mobilities from CE-MS experiments differ from reference values determined by UV detection by similar to 7% depending on the CE-MS interface used. Good agreement of CE-MS and CE-UV data was achieved for nano-sheath liquid flow interface, in which the spray potential and the CE separation potential can be effectively decoupled. As for sheathless porous tip interface, a correction procedure involving a mobility marker has been proposed. It provides typically only ca. 1% difference of effective mobilities and K-st values obtained from CE-MS data as compared to those received by the reference ACE-UV method.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10406 - Analytical chemistry
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2018
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Chromatography A
ISSN
0021-9673
e-ISSN
—
Volume of the periodical
1568
Issue of the periodical within the volume
September
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
8
Pages from-to
197-204
UT code for WoS article
000443669600021
EID of the result in the Scopus database
2-s2.0-85050144898