Assessment of Postural Stability Using the Method of Postural Somatooscilography

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11510%2F19%3A10392473" target="_blank" >RIV/00216208:11510/19:10392473 - isvavai.cz</a>

  • Alternative codes found

    RIV/68407700:21460/19:00340693 RIV/68407700:21720/19:00340693

  • Result on the web

    <a href="https://doi.org/10.1007/978-981-10-9038-7_129" target="_blank" >https://doi.org/10.1007/978-981-10-9038-7_129</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1007/978-981-10-9038-7_129" target="_blank" >10.1007/978-981-10-9038-7_129</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Assessment of Postural Stability Using the Method of Postural Somatooscilography

  • Original language description

    The aim of article is to present new method for evaluating the postural stability using oscillating platform. Proposed methods are alternative to basic methods which are usually parts of the commercial posturography systems. The methods for calculating the postural parameters have been designed in order to objectively quantify and classify the ability of postural stabilization on a standardized oscillatory platform, and determine differences in the postural stabilization of motor function in healthy people and in people with postural instability. The Posturomed (Haider Bioswing GmbH) and biaxial accelerometer sensor were used for measurement the body acceleration during single leg stance provocation test. The postural somatooscilogram has been defined, which shows accelerations of platform, in horizontal plane in both anteroposterior and mediolateral directions over time. Two parameters, Average Damping Coefficient (ADC) and Average Coefficient of Damped Energy (ACDE), were used to evaluate postural stability. The proposed method was implemented in MatLab sw. Patients with postural disorders and control group of healthy subjects were measured. Statistically significant differences have been observed in postural stability between independent postural stable group and postural unstable groups. Based on the findings, we can say that the presented method allows a complex analysis of the single leg stance in patients with postural balance disorders in clinical practice.

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

  • OECD FORD branch

    30306 - Sport and fitness sciences

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2019

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018

  • ISBN

    978-981-10-9038-7

  • ISSN

    1680-0737

  • e-ISSN

  • Number of pages

    5

  • Pages from-to

    697-701

  • Publisher name

    SPRINGER

  • Place of publication

    NEW YORK

  • Event location

    Prague

  • Event date

    Jun 3, 2018

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article

    000449742700129