Comparison of Bioelectrical Impedance Analysis and Air Displacement Plethysmography
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11510%2F19%3A10396135" target="_blank" >RIV/00216208:11510/19:10396135 - isvavai.cz</a>
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=NLKNIKymUF" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=NLKNIKymUF</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4067/S0717-95022019000300985" target="_blank" >10.4067/S0717-95022019000300985</a>
Alternative languages
Result language
angličtina
Original language name
Comparison of Bioelectrical Impedance Analysis and Air Displacement Plethysmography
Original language description
The measurement of body composition has become an important component in the diagnosis of health, physical conditioning and nutritional status. The aim of this study was to compare two methods of detecting body composition, bioelectrical impedance and air displacement plethysmography for athletes and non-athletes. Specifically, we compared the parameters as fat mass, fat free mass and the value of basal metabolic rate. A sample size of 52 men (age 26.2 +/- 5.4 years) that included a group of mixed martial arts (MMA) fighters (n = 31, age 27.2 +/- 5.5 years) and a group of the non-athletes (n = 21, age 24.6 +/- 5.1 years). Both groups were measured by bioelectrical impedance and air displacement plethysmography. Significant differences in % body fat (p<0.05) and fat-free mass (p<0.05) were noted between bioelectrical impedance and air displacement plethysmography of non-athletes, but there were no significant differences for athletes. Furthermore, there was a significant difference (p<0.001) of basal metabolic rate between bioelectrical impedance and air displacement plethysmography, but the correlation with fat free mass was very strong for both methods. Therefore, the use of bioelectrical impedance and air displacement plethysmography may be useful for detecting changes in body composition, but their accuracy is controversial and for this reason we recommend using only one method and not combining them.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30306 - Sport and fitness sciences
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2019
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
International Journal of Morphology [online]
ISSN
0717-9502
e-ISSN
—
Volume of the periodical
37
Issue of the periodical within the volume
3
Country of publishing house
CL - CHILE
Number of pages
6
Pages from-to
985-990
UT code for WoS article
000476478000032
EID of the result in the Scopus database
2-s2.0-85069821793