Single balloon enteroscopy for endoscopic retrograde cholangiography in patients with Roux-en-Y hepaticojejuno anastomosis
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F13%3A00071030" target="_blank" >RIV/00216224:14110/13:00071030 - isvavai.cz</a>
Alternative codes found
RIV/61988987:17110/13:A140194N RIV/00159816:_____/13:00060673
Result on the web
<a href="http://dx.doi.org/10.3748/wjg.v19.i44.8047" target="_blank" >http://dx.doi.org/10.3748/wjg.v19.i44.8047</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3748/wjg.v19.i44.8047" target="_blank" >10.3748/wjg.v19.i44.8047</a>
Alternative languages
Result language
angličtina
Original language name
Single balloon enteroscopy for endoscopic retrograde cholangiography in patients with Roux-en-Y hepaticojejuno anastomosis
Original language description
AIM: To evaluate single balloon enteroscopy in diagnostic and therapeutic endoscopic retrograde cholangiography (ERC) in patients with Roux-en-Y hepaticojejunoanastomosis (HJA). METHODS: The study took place from January 2009 to December 2011 and we retrospectively assessed 15 patients with Roux-en-Y HJA who had signs of biliary obstruction. In total, 23 ERC procedures were performed in these patients and a single balloon videoen-teroscope (Olympus SIF Q 180) was used in all of the cases. A transparentovertube was drawn over the videoenteroscope and it freely moved on the working part of the enteroscope. Its distal end was equipped with a silicone balloon that was inflated by air from an external pump at a pressure of <= 5.4 kPa. The technical limitations or rather the parameters of the single balloon enteroscope (working length - 200 cm, diameter of the working channel - 2.8 mm, absence of Albarran bridge) showed the need for special endoscopic instrumentation.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
FE - Other fields of internal medicine
OECD FORD branch
—
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2013
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
WORLD JOURNAL OF GASTROENTEROLOGY
ISSN
1007-9327
e-ISSN
—
Volume of the periodical
19
Issue of the periodical within the volume
44
Country of publishing house
CN - CHINA
Number of pages
9
Pages from-to
8047-8055
UT code for WoS article
000327519300025
EID of the result in the Scopus database
—