All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Correlation between Parameters of Brain Tissue Oxygen Monitoring and Transcranial Dopplermetry in Patients with Severe Subarachnoid Hemorrhage

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F13%3A00071181" target="_blank" >RIV/00216224:14110/13:00071181 - isvavai.cz</a>

  • Alternative codes found

    RIV/65269705:_____/13:#0002186

  • Result on the web

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    angličtina

  • Original language name

    Correlation between Parameters of Brain Tissue Oxygen Monitoring and Transcranial Dopplermetry in Patients with Severe Subarachnoid Hemorrhage

  • Original language description

    Objectives: it is still difficult to define vasospasms in patients with severe subarachnoid hemorrhage according to the tissue oxymetry monitoring. The aim of this study is to evaluate correlation between brain tissue oxygen levels and transcranial dopplermetry parameters in patients suffering from severe subarachnoid hemorrhage (SAH). Methods: Patients with SAH from a rupture of cerebral vessel aneurysm in clinical status of HH4 and 5 according to Hunt-Hess scale were enrolled into the study. Brain tissue oxygen monitoring (PbtO2, Licox system) of the area supplied by the ipsilateral middle cerebral artery was performed in addition to standard ICU monitoring. Transcranial dopplermetry (TCD) of the ipsilateral middle cerebral artery was performed repeatedly. The correlation between TCD parameters and parameters of PbtO2 was evaluated. Results: Totally we have enrolled 27 patients, 5 patients were subsequently excluded because of bad position of the probe or early failure of PbtO2 monit

  • Czech name

  • Czech description

Classification

  • Type

    O - Miscellaneous

  • CEP classification

    FH - Neurology, neuro-surgery, nuero-sciences

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/NT11092" target="_blank" >NT11092: Monitoring of tissue oxymetry and cerebral blood flow for detection and treatment of cerebral ischemia in patients after severe subarachnoid hemorrhage</a><br>

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2013

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů