Contribution of sVEP visual acuity testing in comparison with subjective visual acuity
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F15%3A00085194" target="_blank" >RIV/00216224:14110/15:00085194 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.5507/bp.2015.002" target="_blank" >http://dx.doi.org/10.5507/bp.2015.002</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.5507/bp.2015.002" target="_blank" >10.5507/bp.2015.002</a>
Alternative languages
Result language
angličtina
Original language name
Contribution of sVEP visual acuity testing in comparison with subjective visual acuity
Original language description
Aims: Visual acuity determination is an important task in ophthalmology and optometry practices. Visual acuity can be examined objectively or subjectively. The objective examination method, sVEP, allows for quick objective measurements of patient's visual acuity. Previous studies have not demonstrated the repeatability of this objective sVEP method. This study aims to evaluate the sVEP method and compare it to a subjective method. Methods and Results: The sample was divided into two groups. For the first group, visual acuity was measured with sVEP and Snellen methods on only one patient twelve times. In the second group, visual acuity was measured twice with sVEP followed twice with the Snellen method with Landolt's rings and logMAR modification on 32non-pathological patients. Results showed significant differences between average values of visual acuity obtained with both methods (sVEP and Snellen) in both samples (T-test, P < 0.01; Wilcoxon test, P = 0.02 in second group).
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
FF - ENT (ie. ear, nose, throat), ophthalmology, dentistry
OECD FORD branch
—
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach
Others
Publication year
2015
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Biomedical Papers
ISSN
1213-8118
e-ISSN
—
Volume of the periodical
159
Issue of the periodical within the volume
4
Country of publishing house
CZ - CZECH REPUBLIC
Number of pages
6
Pages from-to
616-621
UT code for WoS article
000366566700016
EID of the result in the Scopus database
—