Limb volume measurements: comparison of accuracy and decisive parameters of the most used present methods

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F15%3A00086429" target="_blank" >RIV/00216224:14110/15:00086429 - isvavai.cz</a>

  • Alternative codes found

    RIV/00159816:_____/15:00063956 RIV/00216305:26620/15:PU119358

  • Result on the web

    <a href="http://dx.doi.org/10.1186/s40064-015-1468-7" target="_blank" >http://dx.doi.org/10.1186/s40064-015-1468-7</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1186/s40064-015-1468-7" target="_blank" >10.1186/s40064-015-1468-7</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Limb volume measurements: comparison of accuracy and decisive parameters of the most used present methods

  • Original language description

    Limb volume measurements are used for evaluating growth of muscle mass and effectivity of strength training. Beside sport sciences, it is used e.g. for detection of oedemas, lymphedemas or carcinomas or for examinations of muscle atrophy. There are several commonly used methods, but there is a lack of clear comparison, which shows their advantages and limits. The accuracy of each method is uncertainly estimated only. The aim of this paper is to determine and experimentally verify their accuracy and compare them among each other. Water Displacement Method (WD), three methods based on circumferential measures?Frustum Sign Model (FSM), Disc Model (DM), Partial Frustum Model (PFM) and two 3D scan based methods Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) were compared. Precise reference cylinders and limbs of two human subjects were measured 10 times by each method. Personal dependency of methods was also tested by measuring 10 times the same object by 3 different people.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    FP - Other medical fields

  • OECD FORD branch

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2015

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    SpringerPlus

  • ISSN

    2193-1801

  • e-ISSN

  • Volume of the periodical

    4

  • Issue of the periodical within the volume

    1

  • Country of publishing house

    CH - SWITZERLAND

  • Number of pages

    15

  • Pages from-to

    1-15

  • UT code for WoS article

    000368709400003

  • EID of the result in the Scopus database