Low contrast media volume in pre-TAVI CT examinations
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F16%3A00089238" target="_blank" >RIV/00216224:14110/16:00089238 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.1007/s00330-015-4080-x" target="_blank" >http://dx.doi.org/10.1007/s00330-015-4080-x</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00330-015-4080-x" target="_blank" >10.1007/s00330-015-4080-x</a>
Alternative languages
Result language
angličtina
Original language name
Low contrast media volume in pre-TAVI CT examinations
Original language description
To evaluate image quality using reduced contrast media (CM) volume in pre-TAVI assessment. Forty-seven consecutive patients referred for pre-TAVI examination were evaluated. Patients were divided into two groups: group 1 BMI < 28 kg/m(2) (n = 29); and group 2 BMI > 28 kg/m(2) (n = 18). Patients received a combined scan protocol: retrospective ECG-gated helical CTA of the aortic root (80kVp) followed by a high-pitch spiral CTA (group 1: 70 kV; group 2: 80 kVp) from aortic arch to femoral arteries. All patients received one bolus of CM (300 mgI/ml): group 1: volume = 40 ml; flow rate = 3 ml/s, group 2: volume = 53 ml; flow rate = 4 ml/s. Attenuation values (HU) and contrast-to-noise ratio (CNR) were measured at the levels of the aortic root (helical) and peripheral arteries (high-pitch). Diagnostic image quality was considered sufficient at attenuation values > 250HU and CNR > 10. Diagnostic image quality for TAVI measurements was obtained in 46 patients.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
FP - Other medical fields
OECD FORD branch
—
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2016
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
European Radiology
ISSN
0938-7994
e-ISSN
—
Volume of the periodical
26
Issue of the periodical within the volume
8
Country of publishing house
US - UNITED STATES
Number of pages
10
Pages from-to
2426-2435
UT code for WoS article
000379192500002
EID of the result in the Scopus database
—