All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Low contrast media volume in pre-TAVI CT examinations

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F16%3A00089238" target="_blank" >RIV/00216224:14110/16:00089238 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1007/s00330-015-4080-x" target="_blank" >http://dx.doi.org/10.1007/s00330-015-4080-x</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1007/s00330-015-4080-x" target="_blank" >10.1007/s00330-015-4080-x</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Low contrast media volume in pre-TAVI CT examinations

  • Original language description

    To evaluate image quality using reduced contrast media (CM) volume in pre-TAVI assessment. Forty-seven consecutive patients referred for pre-TAVI examination were evaluated. Patients were divided into two groups: group 1 BMI &lt; 28 kg/m(2) (n = 29); and group 2 BMI &gt; 28 kg/m(2) (n = 18). Patients received a combined scan protocol: retrospective ECG-gated helical CTA of the aortic root (80kVp) followed by a high-pitch spiral CTA (group 1: 70 kV; group 2: 80 kVp) from aortic arch to femoral arteries. All patients received one bolus of CM (300 mgI/ml): group 1: volume = 40 ml; flow rate = 3 ml/s, group 2: volume = 53 ml; flow rate = 4 ml/s. Attenuation values (HU) and contrast-to-noise ratio (CNR) were measured at the levels of the aortic root (helical) and peripheral arteries (high-pitch). Diagnostic image quality was considered sufficient at attenuation values &gt; 250HU and CNR &gt; 10. Diagnostic image quality for TAVI measurements was obtained in 46 patients.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    FP - Other medical fields

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2016

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    European Radiology

  • ISSN

    0938-7994

  • e-ISSN

  • Volume of the periodical

    26

  • Issue of the periodical within the volume

    8

  • Country of publishing house

    US - UNITED STATES

  • Number of pages

    10

  • Pages from-to

    2426-2435

  • UT code for WoS article

    000379192500002

  • EID of the result in the Scopus database