All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Evaluation of Diastolic Heart Function Using Echocardiography and Pulse Wave Analysis in Patients After Anthracycline Therapy

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F21%3A00122658" target="_blank" >RIV/00216224:14110/21:00122658 - isvavai.cz</a>

  • Result on the web

    <a href="https://ieeexplore.ieee.org/document/9662816" target="_blank" >https://ieeexplore.ieee.org/document/9662816</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.23919/CinC53138.2021.9662816" target="_blank" >10.23919/CinC53138.2021.9662816</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Evaluation of Diastolic Heart Function Using Echocardiography and Pulse Wave Analysis in Patients After Anthracycline Therapy

  • Original language description

    Introduction Diastolic dysfunction plays a crucial role in heart failure. In clinical practice, the standard cardiac examination is echocardiography, where pulse Doppler analysis is used to evaluate diastolic function. The similar parameters could be measured by applanation tonometry. The aim of this study was to determine the correlation between the parameters of diastolic heart function measured by echocardiography and obtained by pulse wave analysis. Methods The study included 92 subjects (41 females) who had been previously treated with anthracycline antibiotics. Pulse waves were registered by the applanation tonometry (Sphygmocor; AtCor Medical, Australia). Each measurement being calibrated by oscillometric method of blood pressure measurement (Omron HEM-907-E instrument, Japan). From the pulse wave we obtained the values of systolic pressure (SBP) and diastolic pressure (DBP), Tension-Time Index (TTI), Diastolic Time Index (DTI) and Subendocardial Viability Ratio (SEVR). With echocardiographic examination (Nemio XG, TOSHIBA, Japan) were estimated parameters of diastolic heart function: E - mitral peak early diastolic filling velocity, A - peak left ventricular filling during atrial contraction, E / A - the ratio of the velocity E a A in left ventricle, IRT - isovolumic relaxation time, DT - deceleration time. Results All measured values were in the physiological range. We found a statistically significant correlation between IRT and DTI, between A, E / A and SEVR. We did not find a significant correlation between the parameters of diastolic function and age or time since the end of treatment. Conclusion From the observed correlation between echocardiography and applanation tonometry, we can assume that the SEVR parameter is suitable for the assessment of diastolic heart function.

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

  • OECD FORD branch

    30105 - Physiology (including cytology)

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2021

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    Computing in Cardiology 2021

  • ISBN

    9781665479165

  • ISSN

    2325-8861

  • e-ISSN

    2325-887X

  • Number of pages

    4

  • Pages from-to

    1-4

  • Publisher name

    IEEE

  • Place of publication

    Neuveden

  • Event location

    Brno

  • Event date

    Sep 12, 2021

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article