All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Effect of isoprenaline and arrhythmogenic conditions on the spontaneous electrical activity of hiPSC-CM with Y4734C-RYR2 variant

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F24%3A00136410" target="_blank" >RIV/00216224:14110/24:00136410 - isvavai.cz</a>

  • Result on the web

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    angličtina

  • Original language name

    Effect of isoprenaline and arrhythmogenic conditions on the spontaneous electrical activity of hiPSC-CM with Y4734C-RYR2 variant

  • Original language description

    Background: In a proband with idiopathic ventricular fibrillation (IF) and in his sister suffering from catecholaminergic polymorphic ventricular tachycardia (CPVT), p.Y4734C-RYR2 variant was found. Here we bring data showing the spontaneous electrical activity of cardiomyocytes derived from human-induced pluripotent stem cells (hiPSC-CM) of the proband (IF), his sister (CPVT), and his healthy nephew as control (WT), and its changes under arrhythmogenic conditions. Methods: The recordings by the multielectrode array technique were performed in control, i.e. in Tyrode solution with 5 mM K+ (5K++37°C), in 0.5 µM isoprenaline (ISO), and under cumulatively added hypokalemia (3K+), β-adrenergic stimulation (ISO), and hyperthermia (40°C). Considering non-normal data distribution, the cycle length (CL) and its short-term variability (STVCL) are shown as the median from n samples and non-parametric tests were used. Results: In 5K+, CPVT hiPSC-CM had a significantly longer CL (1.47 s, n=19; P˂0.05) than IF (1.05 s, n=32) and WT (0.77 s, n=7). ISO significantly shortened CL in all groups (by 38.3, 22.7, and 17.7 % in CPVT, IF, and WT, respectively, n=19, 32, and 7; P ˂ 0.05) and CPVT showed a significantly larger reaction than IF (P˂0.05). The arrhythmogenic factors caused a significant increment in STVCL in IF (41.91 in 3K+, 22.65 in 3K++ISO, and 65.38 ms in 3K++ISO+40°C, vs. 10.23 ms in control; n=24; P˂0.05) whereas it was significantly increased only in 3K+ in CPVT (21.14, 15.99, and 10.44 ms, respectively, vs. 13.13 in control; n=20; P˂0.05). IF and CPVT significantly differed in STVCL in 3K++ISO+40°C. Conclusions: CPVT hiPSC-CM showed a lower frequency of spontaneous activity and its higher reactivity to ISO. An increment in beat-to-beat variability of CL was observed during arrhythmogenic conditions in IF hiPSC-CM.

  • Czech name

  • Czech description

Classification

  • Type

    O - Miscellaneous

  • CEP classification

  • OECD FORD branch

    30201 - Cardiac and Cardiovascular systems

Result continuities

  • Project

    <a href="/en/project/NU22-02-00348" target="_blank" >NU22-02-00348: Functional assessment of genetic variants in clinically “true” cases of idiopathic ventricular fibrillation: in vitro and in silico modelling to reveal the arrhythmogenic mechanism</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2024

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů