SSP silicone-, lipid- and SPMD-water partition coefficients of seventy hydrophobic organic contaminants and evaluation of the water concentration calculator for SPMD
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F19%3A00107554" target="_blank" >RIV/00216224:14310/19:00107554 - isvavai.cz</a>
Result on the web
<a href="https://www.sciencedirect.com/science/article/pii/S0045653519301808?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0045653519301808?via%3Dihub</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.chemosphere.2019.01.164" target="_blank" >10.1016/j.chemosphere.2019.01.164</a>
Alternative languages
Result language
angličtina
Original language name
SSP silicone-, lipid- and SPMD-water partition coefficients of seventy hydrophobic organic contaminants and evaluation of the water concentration calculator for SPMD
Original language description
Passive sampling is increasingly applied for monitoring neutral hydrophobic compounds (HOC) in various environmental media like water, sediment, air and also soft biota tissue. Passive samplers for HOC are often constructed from permeable polymers like silicone and polyethylene (PE), while also SPMD are often applied. Their HOC uptake can be converted to freely dissolved or equivalent lipid-based concentrations using appropriate partition coefficients with or without the use of kinetic uptake models to adjust for non-equilibrium. To facilitate such conversions for seventy HOC partition coefficients are derived by combining polymer-water for Altesil (TM) silicone and PE, with new and earlier published polymer-polymer, polymer-lipid partition coefficients. Derived SSP silicone-water, lipid-water (K-lip/w), and SPMD-water (K-spmd/w) partition coefficients demonstrate good agreement with literature data, except for K-spmd/w. For SPMD, this work demonstrates a linear K-spmd/w - K-ow relationship (R-2 = 0.99) in contrast to the parabolic K-spmd/w - K-ow relationship utilized in the USGS "SPMD Water Concentrations Calculator". Following a thorough evaluation of this Calculator it is recommended that in combination with revised K-spmd/w, a radical different model approach should be used for obtaining accurate water concentrations from passive sampling with SPMD. (C) 2019 Elsevier Ltd. All rights reserved.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10511 - Environmental sciences (social aspects to be 5.7)
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2019
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Chemosphere
ISSN
0045-6535
e-ISSN
1879-1298
Volume of the periodical
223
Issue of the periodical within the volume
May
Country of publishing house
GB - UNITED KINGDOM
Number of pages
10
Pages from-to
748-757
UT code for WoS article
000465054600081
EID of the result in the Scopus database