Emerging investigator series: air conditioning filters as a sampler for semi-volatile organic compounds in indoor and near-building air
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F20%3A00114763" target="_blank" >RIV/00216224:14310/20:00114763 - isvavai.cz</a>
Result on the web
<a href="https://doi.org/10.1039/D0EM00284D" target="_blank" >https://doi.org/10.1039/D0EM00284D</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1039/d0em00284d" target="_blank" >10.1039/d0em00284d</a>
Alternative languages
Result language
angličtina
Original language name
Emerging investigator series: air conditioning filters as a sampler for semi-volatile organic compounds in indoor and near-building air
Original language description
Organic compounds like flame retardants (FRs), polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs) and polycyclic aromatic hydrocarbons (PAHs) are consistently found in both indoor and outdoor environments. There are many possible matrices for measurement of these compounds (e.g. indoor dust, air - passive and active air samples), but all methods have limitations, like the heterogeneous distribution of indoor dust, or noisy active air samplers. We used filters from building-wide heating, ventilation and air conditioning (HVAC) units to evaluate levels of PAHs, PCBs, OCPs and NFRs in indoor and outdoor environments, and to evaluate whether this method is feasible for screening semivolatile organic compounds (SVOCs) in indoor and near-building outdoor environments. Detectable levels of FRs, PCBs, OCPs and PAHs were found, demonstrating that HVAC filters do collect SVOCs, with generally higher levels of PAHs in the incoming air filters and higher levels of PCBs, OCPs and FRs in the outgoing air filters. Levels of FRs, PCBs and OCPs in outgoing air were comparable to those measured using conventional active air sampling in the same building. The advantages of using HVAC filters are (1) integrated and homogeneous samples, as the whole building is sampled over typically a long timescale (months), and (2) samples are easy and cheap to collect and do not require prior deployment of samplers. The key disadvantage is that HVAC filters are not designed for analytical chemistry and thus the filter materials can have variable or unknown gas sorption and particle capture, and can have strong matrix effects during analysis.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10511 - Environmental sciences (social aspects to be 5.7)
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2020
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Environmental Science: Processes and Impacts
ISSN
2050-7887
e-ISSN
2050-7895
Volume of the periodical
22
Issue of the periodical within the volume
12
Country of publishing house
GB - UNITED KINGDOM
Number of pages
10
Pages from-to
2322-2331
UT code for WoS article
000599425400003