All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Laser-induced breakdown spectroscopy in analysis of algae contamination on the filter

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F22%3A00126686" target="_blank" >RIV/00216224:14310/22:00126686 - isvavai.cz</a>

  • Result on the web

    <a href="http://esas-cssc2022.spektroskopie.cz/" target="_blank" >http://esas-cssc2022.spektroskopie.cz/</a>

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    angličtina

  • Original language name

    Laser-induced breakdown spectroscopy in analysis of algae contamination on the filter

  • Original language description

    The heavy metal contamination of algae on a filter was directly monitored with laser-induced breakdown spectroscopy (LIBS) as a demonstration of LIBS capabilities. To enhance the LIBS sensitivity, single or double pulse arrangements employing 1064 and 532 nm lasers, noble gasses or nanoparticles were tested. Liquid samples of the green alga Desmodesmus subspicatus were intentionally contaminated with chromium, nickel or zinc, incubated, filtered, and the filters with the algae were analysed. Also laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was used for comparison and (ICP-MS) was used as a reference method. One half of the filter with the algae was dissolved and analysed as a solution with ICP-MS and the second half was subjected to the LIBS and LA-ICP-MS analysis. The metals were attributable to the algae contamination and detectable with LIBS. The results from the LIBS provided almost equivalent information about the relative changes of the contaminants concentration in the algae. The LIBS sensitivity with a Czerny-Turner spectrometer was fully comparable with the ICP-MS procedure. The LIBS trends were more similar to the LA-ICP-MS ones. The algae growth inhibition in dependence on the contaminant content, number of cells and the rate of cell contamination can be alternatively monitored with LIBS instead of the complicated procedure in ICP-MS analysis.

  • Czech name

  • Czech description

Classification

  • Type

    O - Miscellaneous

  • CEP classification

  • OECD FORD branch

    10406 - Analytical chemistry

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2022

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů