Retention prediction of monoamine neurotransmitters in gradient liquid chromatography

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F22%3A00129212" target="_blank" >RIV/00216224:14310/22:00129212 - isvavai.cz</a>

  • Result on the web

    <a href="https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/10.1002/jssc.202200201" target="_blank" >https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/10.1002/jssc.202200201</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1002/jssc.202200201" target="_blank" >10.1002/jssc.202200201</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Retention prediction of monoamine neurotransmitters in gradient liquid chromatography

  • Original language description

    Retention prediction of monoamine neurotransmitters has been compared for the generally applied linear solvent-strength model and quadratic polynomial three-parameter model. The design of experiments protocol has been applied to plan linear gradients within the experimental space with altered gradient time, mobile phase flow rate, and column temperature. Relative prediction errors increased at elevated temperature, which is more significant for the linear solvent-strength model when compared to the polynomial model. On the other hand, the predefined design of experiments space controls the retention time errors, as predictions for LC conditions that are outside of the plan are much less accurate and should be avoided. The final part of the work deals with the effect of extracolumn band dispersion on the peak capacity of linear gradients at various gradient times, mobile phase flow rates, and column temperature. The peak capacity determined for corrected experimental data were consistent with the published results dealing with the optimization of peak capacity in gradient elution.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10406 - Analytical chemistry

Result continuities

  • Project

    <a href="/en/project/GA20-21903S" target="_blank" >GA20-21903S: Segmented two-dimensional liquid chromatography</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2022

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Journal of Separation Science

  • ISSN

    1615-9306

  • e-ISSN

    1615-9314

  • Volume of the periodical

    45

  • Issue of the periodical within the volume

    17

  • Country of publishing house

    DE - GERMANY

  • Number of pages

    9

  • Pages from-to

    3319-3327

  • UT code for WoS article

    000832553700001

  • EID of the result in the Scopus database