All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Harmonized quality assurance/quality control provisions to assess completeness and robustness of MS1 data preprocessing for LC-HRMS-based suspect screening and non-targeted analysis

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F24%3A00136130" target="_blank" >RIV/00216224:14310/24:00136130 - isvavai.cz</a>

  • Result on the web

    <a href="https://www.sciencedirect.com/science/article/pii/S0165993624001560?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0165993624001560?via%3Dihub</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.trac.2024.117674" target="_blank" >10.1016/j.trac.2024.117674</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Harmonized quality assurance/quality control provisions to assess completeness and robustness of MS1 data preprocessing for LC-HRMS-based suspect screening and non-targeted analysis

  • Original language description

    Non-targeted and suspect screening analysis using liquid chromatography coupled to high-resolution mass spectrometry (LC-HRMS) holds great promise to comprehensively characterize complex chemical mixtures. Data preprocessing is a crucial part of the process, however, some limitations are observed: (i) peak-picking and feature extraction might be incomplete, especially for low abundant compounds, and (ii) limited reproducibility has been observed between laboratories and software for detected features and their relative quantification. We first conducted a critical review of existing solutions that could improve the reproducibility of preprocessing for LC-HRMS. Solutions include providing repositories and reporting guidelines, open and modular processing workflows, public benchmark datasets, tools to optimize the data preprocessing and to filter out false positive detections. We then propose harmonized quality assurance/quality control guidelines that would allow to assess the sensitivity of feature detection, reproducibility, integration accuracy, precision, accuracy, and consistency of data preprocessing for human biomonitoring, food and environmental communities.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10406 - Analytical chemistry

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2024

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    TrAC Trends in Analytical Chemistry

  • ISSN

    0165-9936

  • e-ISSN

  • Volume of the periodical

    174

  • Issue of the periodical within the volume

    May 2024

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    13

  • Pages from-to

    1-13

  • UT code for WoS article

    001223574100001

  • EID of the result in the Scopus database

    2-s2.0-85189750851