Acoustic signal in overcoming the matrix effect in LIBS: Toward reliable applicability
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F25%3A00141960" target="_blank" >RIV/00216224:14310/25:00141960 - isvavai.cz</a>
Result on the web
<a href="https://www.sciencedirect.com/science/article/pii/S0584854725000254?via%3Dihub#ac0005" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0584854725000254?via%3Dihub#ac0005</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.sab.2025.107140" target="_blank" >10.1016/j.sab.2025.107140</a>
Alternative languages
Result language
angličtina
Original language name
Acoustic signal in overcoming the matrix effect in LIBS: Toward reliable applicability
Original language description
The versatility of laser-induced breakdown spectroscopy (LIBS) resulting from its advantageous analytical characteristics is, unfortunately, still limited by challenges inherent to the fundamental principles of the method - the processes of laser ablation and laser-induced plasma generation. Unwanted effects (generally known as matrix effects) significantly decrease the analytical performance of LIBS, complicating quantification and impairing reproducibility. This study investigates acoustic signals accompanying plasmas (LIPAc) to overcome these limitations and enhance LIBS performance. The influence of instrumental (microphone types), operational (laser wavelength and fluence) and sample parameters on acoustic responses were evaluated. The results indicate that laser fluence strongly influences acoustic wave oscillation. When laser fluence substantially exceeds the breakdown thresholds of the different components in the matter, acoustic responses may become identical across various materials. On the other hand, proportionality in differences of acoustic signal is maintained for different microphones and laser wavelength settings. Promising solutions for eliminating matrix effects on various surfaces were identified, but the suitability and efficiency may be highly dependent on the emission line used. This is demonstrated using the signals of atomic Cu(I) 324.74 nm and ionic Cu(II) 329.04 nm lines measured from an aluminum sample with a partially coppered and partially roughened surface. Acoustic maps of a galena ore sample demonstrate the applications of LIPAc in spatially resolved LIBS imaging and elemental mapping. These maps can help eliminate the discrepancy between the intensities of the calcium atomic line of Ca(I) at 422.67 nm measured from the galena mineral and calcium carbonate.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10406 - Analytical chemistry
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach
Others
Publication year
2025
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY
ISSN
0584-8547
e-ISSN
1873-3565
Volume of the periodical
226
Issue of the periodical within the volume
APR
Country of publishing house
GB - UNITED KINGDOM
Number of pages
12
Pages from-to
1-12
UT code for WoS article
001426626100001
EID of the result in the Scopus database
2-s2.0-85217418800