Effect of stationary phase surface chemistry and particle architecture in proteomics
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F25%3A00144324" target="_blank" >RIV/00216224:14310/25:00144324 - isvavai.cz</a>
Result on the web
<a href="https://doi.org/10.1016/j.chroma.2025.465976" target="_blank" >https://doi.org/10.1016/j.chroma.2025.465976</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.chroma.2025.465976" target="_blank" >10.1016/j.chroma.2025.465976</a>
Alternative languages
Result language
angličtina
Original language name
Effect of stationary phase surface chemistry and particle architecture in proteomics
Original language description
The kinetic properties of four columns packed with fully porous particles and three with superficially porous particles were characterized for possible application in proteomic bottom-up analyses. All columns provided an attachment of hydrophobic C18 chains at the surface of the stationary phase. However, they differed in the additional attachment of polar groups and/or endcapping procedure. We have used the retention modeling protocol to explore the separation efficiency and maximal achievable peak capacity on tested columns. Almost all columns provided comparable maximal peak capacity in the range of 500 - 700 for the eight-hour gradient run. This confirms that the family of the stationary phases used in the bottom-up proteomics can be extended. In the case of fully porous particles, we found that the higher the column peak capacity, the higher the number of identified peptides in the simple proteomic sample, with approximately one identified peptide per peak capacity unit. On the contrary, in the case of the superficially porous particles, the number of identified peptides in the sample decreased with the higher column peak capacity. This trend can be overturned only when the lower amount of the sample is injected. Hence, when bottom-up proteomics is considered, the lower loadability of the superficially porous particles still needs to be addressed. Most stationary phases tested can be successfully used in the bottom-up analyses. However, the stationary phases with incorporated polar functional groups reduced the undesirable contribution of free silanol groups to peptide peak tailing and increased the information provided by LC-MS analysis.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10406 - Analytical chemistry
Result continuities
Project
<a href="/en/project/GA23-07581S" target="_blank" >GA23-07581S: Comprehensive top-down-bottom-up proteomics</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2025
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Chromatography
ISSN
0021-9673
e-ISSN
1873-3778
Volume of the periodical
1752
Issue of the periodical within the volume
July
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
8
Pages from-to
465976
UT code for WoS article
001484552900001
EID of the result in the Scopus database